Sharp ER-A450T Service Manual - Page 37
Test termination
View all Sharp ER-A450T manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 37 highlights
Note that when check , or terminates, the termination printout occurs irrespective of any errors that have occurred during the check. (The program terminates normally only when no error print-out has occurred.) ERROR ERROR PRINT Contents 1 E1-ER DR ERn-DRn ERR 2 E2-ER CI ERn-CIn ERR 3 E3-RS CD RSn-CDn ERR 4 E4-RS CS RSn-CSn ERR 5 E5-CI INT Interruption error of CIn 6 E6-CD INT Interruption error of CDn 7 E7-CS INT Interruption error of CSn 8 E8-TXEMP TXEMPn error 9 E9-TXEMP I Interruption error of TXEMPn 10 E10-TXRDY TXRDYn error 11 E11-TXRDY I Interruption error of TXRDYn E12-RCVRDY RCVRDYn error 12 (Reception is impossible. TRQ1 has occurred during execution of check .) 13 E13-RCVRDY I Interruption error of RCVRDY 14 E14-SD RD SDn-RDn ERR (Data error) 15 E15-SD RD SDn-RDn ERR (Data error, Flaming error) E16-TIMER 16 TIMERn error (TMRQn cannot be set after termination of check .) 17 E17-TIMER I Interruption error of TRQ1 Errors that may occur during check (control signal check): E1∼ E7 Errors that may occur during check (data transfer check): E8∼ E15 Errors that may occur during check (timer check): E12, E16 and E17 4) Test termination The program automatically terminates when a check is finished. Termination print-out: 50nn nn : 01 or 50 Ref.:Print generated when an error occurs When no communication is established: (w/o loopback connector) Diag #550 (ch8) Contents of print Diag #501 (ch1) Print of an error encountered first The contents of the printout are different even if the error is the same. 5 - 7