Sharp FO-2970M Service Manual - Page 14

Soft switch description, Soft switch

Page 14 highlights

FO-2970MU 4. Soft switch description • Soft switch SW DATA NO. NO. ITEM 1 Recall interval 2 3 4 SW1 5 Recall times 6 7 8 1 Dial mode 2 Reception mode 3 ECM mode 4 CNG detection in stand-by mode SW2 5 Polling security 6 Automatic cover sheet 7 Junk fax function in manual reception 8 Anti junk fax function 1 Number of rings for auto receive 2 3 4 SW3 5 Automatic switching manual to auto receive 6 mode 7 (0: OFF) 8 Communication results printout 1 (transaction report) 2 3 4 Delay timer before line connect in auto dial SW4 Delay timer of after line connect in auto dial 5 6 Number of CNG detect (STAND-BY mode) 7 8 1 Time format 2 Date format 3 Sender's information transmit 4 Footer print SW5 5 Reserved 6 Substitute reception 7 Substitute reception conditions 8 CSI transmission Switch setting and function 1 0 Binary input 8421 No. = 1 2 3 4 0 1 0 1 (5 x 60 sec = 5 min) Binary input No. = 8421 5678 0 0 1 0 (Twice) Pulse Auto No No On No Yes Yes Binary input No. = Tone Manual Yes Yes Off Yes No No 8421 1234 0 1 0 0 (4 times) Binary input No. = 8421 5678 0 0 0 0 (off) Error Err/Tmr/Mem Send only No print Always No. 1 0 0 0 1 1 No. 2 0 0 1 0 1 No. 3 1 0 0 0 0 3 sec 0 sec 3.6 sec 3.0 sec 1.7 sec 3.0 sec No. 5 1 1 0 0 No. 6 1 0 1 0 1 pulse 2 pulses 3 pulses 4 pulses No. 7 0 0 1 0 No. 8 0 1 0 0 24-hours 12-hours Month-Day-Year Day-Month-Year Off On On Off Off On Reception disable without TSI Reception enable without TSI Off On Initial setting Remarks 0 OPTION 1 Set to 01~15 0 1 0 OPTION 0 Set to 0~10 1 0 0 OPTION 1 Recep key 0 OPTION 0 OPTION 0 FUNC +3 1 OPTION 0 0 OPTION 0 OPTION 1 0 0 0 0 0 0 OPTION 0 0 1 0 0 1 0 1 0 1 0 0 0 0 0 0 2 - 10

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114

FO-2970MU
2 – 10
1
Recall interval
Binary input
8
4
2
1
0
OPTION
2
No. =
1
2
3
4
1
Set to 01~15
3
0
1
0
1
(5 x 60 sec = 5 min)
0
SW1
4
1
5
Recall times
Binary input
8
4
2
1
0
OPTION
6
No. =
5
6
7
8
0
Set to 0~10
7
0
0
1
0
(Twice)
1
8
0
1
Dial mode
Pulse
Tone
0
OPTION
2
Reception mode
Auto
Manual
1
Recep key
3
ECM mode
No
Yes
0
OPTION
SW2
4
CNG detection in stand-by mode
No
Yes
0
OPTION
5
Polling security
On
Off
0
FUNC +3
6
Automatic cover sheet
No
Yes
1
OPTION
7
Junk fax function in manual reception
Yes
No
0
8
Anti junk fax function
Yes
No
0
OPTION
1
Number of rings for auto receive
Binary input
8
4
2
1
0
OPTION
2
No. =
1
2
3
4
1
3
0
1
0
0
(4 times)
0
SW3
4
0
5
Automatic switching manual to auto receive
Binary input
8
4
2
1
0
6
mode
No. =
5
6
7
8
0
7
(0: OFF)
0
0
0
0
(off)
0
8
0
Communication results printout
Error
Err/Tmr/Mem
Send only
No print
Always
OPTION
1
(transaction report)
No. 1
0
0
0
1
1
0
2
No. 2
0
0
1
0
1
0
3
No. 3
1
0
0
0
0
1
4
Delay timer before line connect in auto dial
3 sec
0 sec
0
SW4
Delay timer of after line connect in auto dial
3.6 sec
3.0 sec
1.7 sec
3.0 sec
5
No. 5
1
1
0
0
0
6
No. 6
1
0
1
0
1
Number of CNG detect (STAND-BY mode)
1 pulse
2 pulses
3 pulses
4 pulses
7
No. 7
0
0
1
0
0
8
No. 8
0
1
0
0
1
1
Time format
24-hours
12-hours
0
2
Date format
Month-Day-Year
Day-Month-Year
1
3
Sender’s information transmit
Off
On
0
SW5
4
Footer print
On
Off
0
5
Reserved
0
6
Substitute reception
Off
On
0
7
Substitute reception conditions
Reception disable without TSI
Reception enable without TSI
0
8
CSI transmission
Off
On
0
4. Soft switch description
Soft switch
SW
NO.
DATA
NO.
ITEM
Switch setting and function
Remarks
Initial
setting
1
0