Sharp FO-2970M Service Manual - Page 15

Copy/Send:1m Receive:1.5 m

Page 15 highlights

SW DATA NO. NO. 1 2 3 4 SW6 5 6 7 8 ITEM H2 mode MH fixed Reserved Reserved Modem speed (DCS data reception speed) Reception speed fixed 1 2 3 SW7 4 5 6 7 8 1 2 3 SW8 4 5 6 7 8 1 2 3 SW9 4 5 6 7 8 1 2 3 4 SW10 5 6 7 8 DIS receive acknowledgement during G3 transmission Non modulated carrier for V.29 transmission mode EOL detect timer Protocol monitor Line monitor Length limitation of copy/send/receive Digital line equalization setting (Reception) Dial pausing (sec/pause) Signal transmission level CED tone signal interval Equalizer freeze control (MODEM) Equalizer freeze conditions CED detection time Reserved Reserved Busy tone detection (after auto dial) Reserved Reserved CI off detection timer (Distinctive ring setting off only) Distinctive ringing setting Factory setting : OFF FO-2970MU Switch setting and function 1 0 Initial setting Remarks No Yes 0 Yes No (depends on remote machine) 0 0 0 V.17 V. 29 V. 27ter 14400 12000 9600 7200 9600 7200 4800 2400 No. 5 1111 0 0 0 0 1 No. 6 0000 0 0 0 0 0 No. 7 0101 0 1 1 0 0 No. 8 0011 1 1 0 0 0 No. 1 No. 2 NO V. 17- V. 29- V. 27 ter- 14400 bps 9600 bps 4800 bps 0 1 0 1 0 1 1 0 When 14400 bps modem used, setting to 0 14400 bps is 0 ignored. Twice 0 0 On Off 0 25 sec On On No limit No. 1 No. 2 2sec Binary input No. = 0 Km 0 0 16 8 4 456 010 13 sec Off Off Copy/Send:1m Receive:1.5 m 1.8 Km 3.6 Km 7.2 Km 0 1 1 1 0 1 4sec 21 78 0 1 (-9 dBm) No. 1 No. 2 On All 500 ms 75 ms 0 0 500 ms 750 ms 0 1 1 0 Off 7200 bps 1000 ms 1000 ms 1 1 Yes No No. 3 No. 4 OFF No. 5 0 No. 6 0 No. 7 0 No. 8 0 1200 ms 1000 ms 700 ms 350 ms 0 1 0 1 0 0 1 1 STD RING1 RING2 RING3 RING4 RING5 0 1 0 1 0 1 0 0 1 1 0 0 0 0 0 0 1 1 1 0 0 0 0 0 0 0 0 0 0 0 1 0 1 0 0 1 0 0 0 0 0 0 0 1 0 0 0 1 OPTION 0 RING4/RING5 0 Canada 0 Only 0 2 - 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114

FO-2970MU
2 – 11
1
H2 mode
No
Yes
0
2
MH fixed
Yes
No
(depends on remote machine)
0
3
Reserved
0
4
Reserved
0
SW6
Modem speed
V.17
V. 29
V. 27ter
(DCS data reception speed)
14400
12000
9600
7200
9600
7200
4800
2400
5
No. 5
1
1
1
1
0
0
0
0
1
6
No. 6
0
0
0
0
0
0
0
0
0
7
No. 7
0
1
0
1
0
1
1
0
0
8
No. 8
0
0
1
1
1
1
0
0
0
Reception speed fixed
NO
V. 17-
V. 29-
V. 27 ter-
14400 bps
9600 bps
4800 bps
1
No. 1
0
1
0
1
0
2
No. 2
0
1
1
0
0
3
DIS receive acknowledgement during
Twice
0
0
G3 transmission
SW7
4
Non modulated carrier for V.29
On
Off
0
transmission mode
5
EOL detect timer
25 sec
13 sec
0
6
Protocol monitor
On
Off
0
7
Line monitor
On
Off
0
8
Length limitation of copy/send/receive
No limit
Copy/Send:1m Receive:1.5 m
0
Digital line equalization setting
0 Km
1.8 Km
3.6 Km
7.2 Km
1
(Reception)
No. 1
0
0
1
1
0
2
No. 2
0
1
0
1
0
3
Dial pausing (sec/pause)
2sec
4sec
1
SW8
4
Signal transmission level
Binary input
16
8
4
2
1
0
5
No. =
4
5
6
7
8
1
6
0
1
0
0
1
(–9 dBm)
0
7
0
8
1
CED tone signal interval
75 ms
500 ms
750 ms
1000 ms
1
No. 1
0
0
1
1
0
2
No. 2
0
1
0
1
0
3
Equalizer freeze control (MODEM)
On
Off
0
SW9
4
Equalizer freeze conditions
All
7200 bps
0
5
CED detection time
500 ms
1000 ms
0
6
Reserved
0
7
Reserved
0
8
Busy tone detection (after auto dial)
Yes
No
1
1
Reserved
0
2
Reserved
0
CI off detection timer
1200 ms
1000 ms
700 ms
350 ms
3
(Distinctive ring setting off only)
No. 3
0
1
0
1
0
4
No. 4
0
0
1
1
1
SW10
Distinctive ringing setting
OFF
STD
RING1
RING2
RING3
RING4
RING5
OPTION
5
Factory setting : OFF
No. 5
0
0
1
0
1
0
1
0
RING4/RING5
6
No. 6
0
0
0
1
1
0
0
0
Canada
7
No. 7
0
0
0
0
0
1
1
0
Only
8
No. 8
0
1
0
0
0
0
0
0
SW
NO.
DATA
NO.
ITEM
Switch setting and function
Remarks
Initial
setting
1
0
When 14400 bps
modem used,
setting to
14400 bps is
ignored.