Sharp FO-2970M Service Manual - Page 51
Base machine printing Copy, List, Receiving
View all Sharp FO-2970M manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 51 highlights
2) Protect against overheat Though the heater lamp ON signal (HLON) is normal, if triac PD101 and T2 are kept ON, overheat may result. To prevent against this, temperature fuses are used. When the fusing roller surface temperature exceeds about 187 degrees C, the temperature fuse blows off to open the 12V power line which drives the power relay RY101, opening the power line for the photo triac PD101 and triac T2. Therefore, the power is not supplied to the heater lamp. A temperature fuse is also provided in the heater lamp power line. In case of overheating, the heater lamp power line is opened directly. 3) Timing of temperature detection and heater control As shown by the following timings, four values of software thermistor voltage are input as A/D conversion values. The mean value of two medians among these four is regarded as the newest thermistor value (temperature). • The value is compared with the temperature (155°C) control value every 100 ms. • If the value is higher than 155°C, the heater becomes OFF. If lower, the heater becomes ON. • The heater ON timing is in accordance with the timing of Power Zero Cross interrupt. Heater ON/OFF Control Heater ON/OFF Control T (x 10ms) Inputting thermistor values Timings of thermistor value input and heater control Fig. 13 4) Heater control (Temperature control) Control method 1 Base machine printing (Copy, List, Receiving) • Temperature control is started when data to be printed are produced (or when slips are to be prepared). • Temperature is controlled at 155 °C. (Heater OFF over 155 °C. Heater ON below 155 °C.) • After printing, temperature is not controlled. (Heater is not turned ON.) • Fan motor starts revolving from the beginning of temperature control and stops 120 seconds after printing is finished. 2 PC printing • Temperature control is started when PC starts printing. • Temperature is controlled at 155 °C. (Heater OFF over 155 °C. Heater ON below 155 °C. FO-2970MU • After printing, temperature is not controlled. • Fan motor starts revolving from the beginning of temperature control and stops 120 seconds after printing is finished. Temperature control is not started from the start of printing because the first copying time should be within 28 seconds. In case of the base machine printing (Single sheet continuous printing) 120s 155°C Printing finished HLON FAN Preparation of printing data started Temperature control started OFF CDPAGE (Base machine Printing started) Printing started Fig. 14 155°C In case of PC printing (Single sheet/continuous) Printing finished 120s Printing started HLON FAN CDPAGE (PC printing started) Temperature control started OFF The Heater ON timing is set during Zero Cross interrupt. Fig. 15 5 - 15