Sharp FO-2970M Service Manual - Page 27
SW12 No. 1 ~ No. 5 DTMF signal transmission level Low
View all Sharp FO-2970M manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 27 highlights
SW10 No. 3, No. 4 CI off detection timer (Distinctive ring setting off only) Set the minimum time period of CI signal interruption which affords to be judged as a CI OFF section with 50ms steps. (Example) A B 400msec 1 2000msec 2 1 01 : 700ms (CI interruption>700ms:Judged as a CI OFF section) The section is not judged as a CI OFF section, the CI signal A is 2 counted as one signal. The section is judged as a CI OFF section, the CI signal B is considered as the second signal. 1 11: 350ms (CI interruption>350ms: Judged as a CI OFF section) The section is judged as a CI OFF section, and the CI signal A 2 is counted as two signals. The section is judged as a CI OFF section, and the CI signal B is considered as the third signal. SW10 No. 5 ~ No. 8 Distinctive ringing Factory setting : OFF When the ringing setting is turned off, all of the CI signal are received. When any of the standard, and ring patterns 1 through 4 or 5 is selected for the ringing setting, only the selected CI signal is received. CI signal patterns The CI signal patterns consists of the standard pattern, and ring patterns 1 through 9. The standard pattern is the conventional one. 2S 4S 2S STANDARD 1.5S 1S 1.5S 2S 3S 4S 0.5S RING PATTERN 1 for USA RING PATTERN 2 for USA RING PATTERN 3 for USA RING PATTERN 4 for USA RING PATTERN 1 for CANADA RING PATTERN 2 for CANADA RING PATTERN 3 for CANADA RING PATTERN 4 for CANADA RING PATTERN 5 for CANADA 0.5S 4S 0.8S 0.8S 0.4S 4S 0.3S 1S 0.3S 0.2S 0.2S 4S 0.4S 0.4S 0.8S 0.2S 0.2S 4S 1S 1S 1S 3S 1S 1S 0.5S 0.5S 1S 0.5S 3.5S 0.5S 0.5S 3S 0.5S 0.5S 1S 0.5S 0.5S 3S 0.25S 0.25S 0.25S 0.2S 0.2S 0.25S 0.25S 4.8S 0.2S 5.3S FO-2970MU SW11 No. 1, No. 2 End buzzer The sounding length of the buzzer for normal end of operation set. SW11 No. 3 Communication error treatment in RTN setting mode (reception) Used to determine communication error treatment when RTN is sent by occurrence of a received image error in G3 reception. When it is set to "1", communication error is judged as no error. SW11 No. 4 CNG transmission after auto dialing When set to "0", this model allows CNG transmission by pressing the Start key in the key pad dialing mode. When set to "1", CNG transmission in the key pad dialing mode cannot be performed. In either case. CNG transmission can be performed in the auto dial mode. SW11 No. 5 Error criterion Used to select error criterion for sending back RTN when receiving image data. SW11 No. 6 Pulse to tone change by When setting to 1, the mode is changed by pressing the pulse dial mode to the tone dial mode. key from the SW11 No. 7 CNG transmission in manual transmission CNG signal sending ON/OFF in case of manual transmission is set. SW11 No. 8 Reserved Set to "0". SW12 No. 1 ~ No. 5 DTMF signal transmission level (Low) The transmission level of DTMF signal is adjusted. (lower frequency) 00000 : 0 dBm ↓ 11111 : -15.5 dBm SW12 No. 6 ~ No. 8 Reserved Set to "0". SW13 No. 1 ~ No. 5 DTMF signal transmission level (High) The transmission level of DTMF signal is adjusted. (higher frequency) 00000 : 0 dBm ↓ 11111 : -15.5 dBm SW13 No. 6 ~ No. 8 Reserved Set to "0". SW14 No. 1 ~ No. 3 Reserved Set to "0". SW14 No. 4 , No. 5 Reserved Set to "1". SW14 No. 6 ~ No. 8 Reserved Set to "0". SW15 No.1 ~ No. 8 Reserved Set to "0". SW16 No. 1 Reserved Set to "1". SW16 No. 2 ~ No. 4 Reserved Set to "0". SW16 No. 5 Reserved Set to "1". SW16 No. 6 ~ No. 8 Reserved Set to "0". 2 - 23