Sharp FO-2970M Service Manual - Page 33

Super G3 mode, <Reference> Details of E-29 ~ 31, Service call error massage

Page 33 highlights

Super G3 mode Error Code Transmission Errors Reception Errors E-16 E-17 Same as E-0 Same as E-1 Same as E-0 Same as E-1 E-18 E-19 Same as E-2 − Same as E-2 Same as E-8 E-20 E-21 E-22 E-23 E-24 Same as E-4 − − Same as E-7 Same as E-8 Same as E-9 Same as E-10 − Same as E-7 − E-25 E-26 Same as E-11 Same as E-12 Same as E-11 Same as E-12 E-27 E-28 Same as E-13 − Same as E-13 Same as E-14 E-29 E-30 Error occured during handshaking for super G3 mode E-31 Details of E-29 ~ 31 E-29 Handshaking error in V.8 negotiation procedure E-30 Handshaking error in V.34 line probing procedure E-31 Handshaking error in V.34 HDX training procedure FO-2970MU 2. Service call error massage The following service call errors may occur in FO-2970MU. Message 1 POLYGON ERROR 2 HEATER ERROR 3 HEATER HIGH ERROR 4 HEATER LOW ERROR Description Cause: When the recognition of the laser beam detection signal (HSYNC) is impossible after the printing is started. [HSYNC interruption is usually done once every 846.7µS for PC printing and once every 1298.7524µS for other printing (copying, reception and list).] Cause: When the disconnection of the thermistor is counted 8 times (80ms). Cause: When the temperature of the heater lamp exceeds 188°C during 200 ms. Cause: When the temperature does not exceed 97°C within 15 seconds after the heater lump is ON, or it is less than 97°C even while printing. Only the power on and off can be restored when the service error occurs. 2 - 29

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114

FO-2970MU
2 – 29
Message
Description
1
POLYGON ERROR
Cause: When the recognition of the laser beam detection signal (HSYNC) is impossible after the printing is
started.
[HSYNC interruption is usually done once every 846.7
μ
S for PC printing and once every 1298.7524
μ
S for
other printing (copying, reception and list).]
2
HEATER ERROR
Cause: When the disconnection of the thermistor is counted 8 times (80ms).
3
HEATER HIGH ERROR
Cause: When the temperature of the heater lamp exceeds 188
°
C during 200 ms.
4
HEATER LOW ERROR
Cause: When the temperature does not exceed 97
°
C within 15 seconds after the heater lump is ON, or it is
less than 97
°
C even while printing.
E-29
Handshaking error in V.8 negotiation procedure
E-30
Handshaking error in V.34 line probing procedure
E-31
Handshaking error in V.34 HDX training procedure
Error Code
Transmission Errors
Reception Errors
E-16
Same as E-0
Same as E-0
E-17
Same as E-1
Same as E-1
E-18
Same as E-2
Same as E-2
E-19
-
Same as E-8
E-20
Same as E-4
Same as E-9
E-21
-
Same as E-10
E-22
-
-
E-23
Same as E-7
Same as E-7
E-24
Same as E-8
-
E-25
Same as E-11
Same as E-11
E-26
Same as E-12
Same as E-12
E-27
Same as E-13
Same as E-13
E-28
-
Same as E-14
E-29
E-30
Error occured during handshaking for super G3 mode
E-31
Super G3 mode
<Reference> Details of E-29 ~ 31
2. Service call error massage
The following service call errors may occur in FO-2970MU.
Only the power on and off can be restored when the service error occurs.