Sharp GX20 Service Manual - Page 36
] SHARP RF Test tool manual
View all Sharp GX20 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 36 highlights
GX20 [2] SHARP RF Test tool manual 1. Requirements • PC with COM port • Mouse • GX20 Data Cable • PWB repair jig CONFIDENTIAL 2. Setup Figure 59 PWB repair jig Figure 60 1. Set PWB and make connections as shown in Figures 62 and 63. Make sure connections are correct at the points shown in Figure 64. 2. Connect PC and GX20 with Data Cable. 3. Turn on the phone. 4. Start RF Test Tool. 5. Select a COM port to which Data Cable is connected. 6. Press the "Initialize & Read Data" Button. 7. Figure 61 appears. 8. Click OK to proceed. Figure 61 2 - 30
GX20
2 – 30
CONFIDENTIAL
[2] SHARP RF Test tool manual
1. Requirements
•
PC with COM port
•
Mouse
•
GX20 Data Cable
•
PWB repair jig
Figure 59
PWB repair jig
2. Setup
Figure 60
1.
Set PWB and make connections as shown in Figures 62 and 63.
Make sure connections are correct at the points shown in Figure 64.
2.
Connect PC and GX20 with Data Cable.
3.
Turn on the phone.
4.
Start RF Test Tool.
5.
Select a COM port to which Data Cable is connected.
6.
Press the “Initialize & Read Data” Button.
7.
Figure 61 appears.
8.
Click OK to proceed.