Yamaha CLP-S308PE Owners Manual - Page 68

MIDI Receive Channel Selection, Local Control ON/OFF, Program Change ON/OFF, Setting range

Page 68 highlights

ENGLISH Detailed Settings - [FUNCTION] F7.2: (CLP-370/340)/F7.2: (CLP-S308/S306, CLP-330) MIDI Receive Channel Selection In any MIDI control setup, the MIDI channels of the transmitting and receiving equipment must be matched for proper data transfer. This parameter enables you to specify the channel on which the Clavinova receives MIDI data. Setting range: ALL, 1&2, 1 - 16 Normal setting: ALL NOTE ALL: "Multi-timbre" Receive mode. This allows simultaneous reception of different parts on all 16 MIDI channels, enabling the Clavinova to play multi-channel song data received from F7.6 (CLP-370/340)/ F6.6 (CLP-S308/S306, CLP-330) or sequencer. 1&2: "1&2" Receive mode. This allows simultaneous reception on channels 1 and 2 only, enabling the Clavinova to play 1 and 2 channel song data received from a music computer or sequencer. NOTE Program change and other like channel messages received will not affect the instrument's panel settings or the notes you play on the keyboard. NOTE No MIDI reception occurs when Demo mode is engaged or during file operations. F7.3: (CLP-370/340)/F7.3: (CLP-S308/S306, CLP-330) Local Control ON/OFF "Local Control" refers to the fact that, normally, the keyboard controls its internal tone generator, allowing the internal voices to be played directly from the keyboard. This situation is "Local Control On," since the internal tone generator is controlled locally by its own keyboard. Local control can be turned OFF, however, so that the keyboard does not play the internal voices, but the appropriate MIDI information is still transmitted via the MIDI OUT terminal when notes are played on the keyboard. At the same time, the internal tone generator responds to MIDI information received via the MIDI IN terminal. Setting range: ON/OFF Normal setting: ON F7.4: (CLP-370/340)/F7.4: (CLP-S308/S306, CLP-330) Program Change ON/OFF Normally the instrument will respond to MIDI program change numbers received from an external keyboard or other MIDI device, causing the correspondingly-numbered voice to be selected on the corresponding channel (the keyboard voice does not change). The instrument will normally also send a MIDI program change number whenever one of its voices is selected, causing the correspondingly-numbered voice or program to be selected on the external MIDI device if the device is set up to receive and respond to MIDI program change numbers. This function makes it possible to cancel program change number reception and transmission so that voices can be selected on the instrument without affecting the external MIDI device. NOTE For information on program change numbers for each of the Instrument's voices, Refer to MIDI Data Format on the web site. http://www.yamaha.co.jp/manual/ Setting range: ON/OFF Normal setting: ON F7.5: (CLP-370/340)/F7.5: (CLP-S308/S306, CLP-330) Control Change ON/OFF Normally the CLP-370/340/330, CLP-S308/S306 will respond to MIDI control change data received from an external MIDI device or keyboard, causing the voice on the corresponding channel to be affected by pedal and other "control" settings received from the controlling device (the keyboard voice is not affected). The CLP-370/340/330, CLP-S308/S306 also transmits MIDI control change information when the pedal or other appropriate controls are operated. This function makes it possible to cancel control change data reception and transmission so that, for example, the CLP-370/340/330, CLP-S308/S306's pedal and other controls can be operated without affecting an external MIDI device. NOTE For information on control changes that can be used with the CLP370/340/330, CLP-S308/S306, refer to the MIDI Data Format in our manual library at the following website. http://www.yamaha.co.jp/manual/ Setting range: ON/OFF Normal setting: ON 68 CLP-370/340/330, CLP-S308/S306 Owner's Manual

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108

Detailed Settings – [FUNCTION]
CLP-370/340/330, CLP-S308/S306
Owner’s Manual
ENGLISH
68
F7.2:
(CLP-370/340)
/F7.2:
(CLP-S308/S306, CLP-330)
MIDI Receive Channel Selection
In any MIDI control setup, the MIDI channels of the
transmitting and receiving equipment must be matched
for proper data transfer. This parameter enables you to
specify the channel on which the Clavinova receives
MIDI data.
Setting range:
ALL, 1&2, 1 – 16
Normal setting:
ALL
F7.3:
(CLP-370/340)
/F7.3:
(CLP-S308/S306, CLP-330)
Local Control ON/OFF
“Local Control” refers to the fact that, normally, the key-
board controls its internal tone generator, allowing the
internal voices to be played directly from the keyboard.
This situation is “Local Control On,” since the internal
tone generator is controlled locally by its own keyboard.
Local control can be turned OFF, however, so that the
keyboard does not play the internal voices, but the
appropriate MIDI information is still transmitted via the
MIDI OUT terminal when notes are played on the key-
board. At the same time, the internal tone generator
responds to MIDI information received via the MIDI IN
terminal.
Setting range:
ON/OFF
Normal setting:
ON
F7.4:
(CLP-370/340)
/F7.4:
(CLP-S308/S306, CLP-330)
Program Change ON/OFF
Normally the instrument will respond to MIDI program
change numbers received from an external keyboard or
other MIDI device, causing the correspondingly-num-
bered voice to be selected on the corresponding channel
(the keyboard voice does not change). The instrument
will normally also send a MIDI program change number
whenever one of its voices is selected, causing the corre-
spondingly-numbered voice or program to be selected
on the external MIDI device if the device is set up to
receive and respond to MIDI program change numbers.
This function makes it possible to cancel program
change number reception and transmission so that
voices can be selected on the instrument without affect-
ing the external MIDI device.
Setting range:
ON/OFF
Normal setting:
ON
F7.5:
(CLP-370/340)
/F7.5:
(CLP-S308/S306, CLP-330)
Control Change ON/OFF
Normally the CLP-370/340/330, CLP-S308/S306 will
respond to MIDI control change data received from an
external MIDI device or keyboard, causing the voice on
the corresponding channel to be affected by pedal and
other “control” settings received from the controlling
device (the keyboard voice is not affected).
The CLP-370/340/330, CLP-S308/S306 also transmits
MIDI control change information when the pedal or
other appropriate controls are operated.
This function makes it possible to cancel control change
data reception and transmission so that, for example, the
CLP-370/340/330, CLP-S308/S306’s pedal and other
controls can be operated without affecting an external
MIDI device.
Setting range:
ON/OFF
Normal setting:
ON
NOTE
ALL:
“Multi-timbre” Receive mode. This allows simultaneous reception of
different parts on all 16 MIDI channels, enabling the Clavinova to
play multi-channel song data received from F7.6 (CLP-370/340)/
F6.6 (CLP-S308/S306, CLP-330) or sequencer.
1&2:
“1&2” Receive mode. This allows simultaneous reception on chan-
nels 1 and 2 only, enabling the Clavinova to play 1 and 2 channel
song data received from a music computer or sequencer.
NOTE
Program change and other like channel messages received will not
affect the instrument’s panel settings or the notes you play on the
keyboard.
NOTE
No MIDI reception occurs when Demo mode is engaged or during
file operations.
NOTE
For information on program change numbers for each of the Instru-
ment’s voices, Refer to MIDI Data Format on the web site.
NOTE
For information on control changes that can be used with the CLP-
370/340/330, CLP-S308/S306, refer to the MIDI Data Format in our
manual library at the following website.