Yamaha CLP-S308PE Owners Manual - Page 69

Panel/Status Transmit, Procedure, Initial Setup Send, Detailed Settings - [FUNCTION]

Page 69 highlights

ENGLISH F7.6: (CLP-370/340)/ F7.6: (CLP-S308/S306, CLP-330) Panel/Status Transmit This function causes all the current instrument panel settings (selected voice, etc.) to be transmitted via the MIDI OUT terminal. TERMINOLOGY Setup Data: Data that contains a set of panel settings for the Clavinova. Procedure 1. Set up the panel controls as desired. 2. Connect the Clavinova to a sequencer via MIDI, and set up the sequencer so it can receive the setup data. 3. Engage the Function mode and select (CLP- 370/340)/ (CLP-S308/S306, CLP-330). 4. Press the [+/YES] button to transmit the panel/status data. will appear on the LED display when the data has been successfully transmitted. NOTE For a list of the "Panel Data Contents" transmitted by this function, refer to our manual library at the following website. http://www.yamaha.co.jp/manual/ NOTE Receiving the transmitted data: 1. Connect the Clavinova via MIDI to the device to which the setup data was transmitted previously. 2. Start sending the setup data from the device. The Clavinova automatically receives the setup data, which will be reflected in the panel settings. (For the data to be accepted, the Clavinova that receives the setup data should be the same model as the one that transmitted the setup data to the sequencer.) NOTE For more information on transmitting and receiving setup data via MIDI, refer to the owner's manual for the connected MIDI device. Detailed Settings - [FUNCTION] F7.7: (CLP-370/340)/F7.7: (CLP-S308/S306, CLP-330) Initial Setup Send This function lets you send the data of the panel settings to a computer. By transmitting the panel settings and recording them on the MIDI sequence recorder prior to the actual performance data, the instrument will be automatically restored to the same settings when the performance is played back. You can also use this function to change the settings of a connected tone generator to the same settings as the instrument. Procedure 1. Set up the panel controls as desired. 2. Connect the Clavinova to a sequencer via MIDI, and set up the sequencer so it can receive the setup data. 3. Engage the Function mode and select (CLP- 370/340)/ (CLP-S308/S306, CLP-330). 4. Press the [+/YES] button to transmit the panel/status data. will appear on the LED display when the data has been successfully transmitted. The following data can be sent. • Voice selection • [REVERB] type • [REVERB] depth • [EFFECT] type • [EFFECT] depth • Split point • Tuning (F1) • Dual detune (F3.2) CLP-370/340/330, CLP-S308/S306 Owner's Manual 69

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108

Detailed Settings – [FUNCTION]
CLP-370/340/330, CLP-S308/S306
Owner’s Manual
ENGLISH
69
F7.6:
(CLP-370/340)
/
F7.6:
(CLP-S308/S306, CLP-330)
Panel/Status Transmit
This function causes all the current instrument panel set-
tings (selected voice, etc.) to be transmitted via the MIDI
OUT terminal.
Procedure
1.
Set up the panel controls as desired.
2.
Connect the Clavinova to a sequencer via MIDI, and
set up the sequencer so it can receive the setup data.
3.
Engage the Function mode and select
(CLP-
370/340)/
(CLP-S308/S306, CLP-330).
4.
Press the
[+/YES]
button to transmit the panel/status
data.
will appear on the LED display when the data has
been successfully transmitted.
F7.7:
(CLP-370/340)
/F7.7:
(CLP-S308/S306, CLP-330)
Initial Setup Send
This function lets you send the data of the panel settings
to a computer. By transmitting the panel settings and
recording them on the MIDI sequence recorder prior to
the actual performance data, the instrument will be
automatically restored to the same settings when the per-
formance is played back. You can also use this function to
change the settings of a connected tone generator to the
same settings as the instrument.
Procedure
1.
Set up the panel controls as desired.
2.
Connect the Clavinova to a sequencer via MIDI, and
set up the sequencer so it can receive the setup data.
3.
Engage the Function mode and select
(CLP-
370/340)/
(CLP-S308/S306, CLP-330).
4.
Press the
[+/YES]
button to transmit the panel/status
data.
will appear on the LED display when the data has
been successfully transmitted.
The following data can be sent.
Voice selection
[REVERB] type
[REVERB] depth
[EFFECT] type
[EFFECT] depth
Split point
Tuning (F1)
Dual detune (F3.2)
TERMINOLOGY
Setup Data:
Data that contains a set of panel settings for the Clavinova.
NOTE
For a list of the “Panel Data Contents” transmitted by this function,
refer to our manual library at the following website.
NOTE
Receiving the transmitted data:
1.
Connect the Clavinova via MIDI to the device to which the setup
data was transmitted previously.
2.
Start sending the setup data from the device.
The Clavinova automatically receives the setup data, which will be
reflected in the panel settings.
(For the data to be accepted, the Clavinova that receives the setup
data should be the same model as the one that transmitted the
setup data to the sequencer.)
NOTE
For more information on transmitting and receiving setup data via
MIDI, refer to the owner’s manual for the connected MIDI device.