Identifying Which Fan has Failed, Hot Swapping Disk Drives
UPC - 753253020577
View all Adaptec 5325302057 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 150 highlights
Hot Swapping Disk Drives Identifying Which Fan has Failed If the fan icon shows a failed fan, you can determine which fan failed by selecting the affected server in the Enterprise View, then double-clicking the Enclosure Management Device icon to open the Properties window for the server. Click the Status tab, then scroll through the list of enclosure components. A yellow or red exclamation point will appear next to the problem component. Hot Swapping Disk Drives The term hot swap refers to the ability to remove and add components to a system without the need to turn off the server or interrupt client access. Caution Do not hot swap a disk drive that is part of a pool, volume, or logical device. You may lose data and pool configuration information if you do. You can hot swap disk drives on a Snap Server 700i Series or SANbloc S50 RAID 1, 5, 6, 10, 50, 60, or 1E by following the basic steps outlined next: 1 Remove the front bezel by pressing in the latches on each side of the bezel and pulling the bezel away from the chassis (700i Series only). 2 On the closed handle of the failed disk drive, press the button in and to the left to release the latch. 3 Open the handle and pull to remove the drive from the chassis. 144 Snap Server 700i Series User's Guide