Warning., Correct Polarity Connections
View all Alcatel OS6850-P48 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 147 highlights
OmniSwitch 6850/6850E Series Power Supplies OmniSwitch 6850/6850E Series Power Supplies 4 Tighten the clamp by tightening the screw above the slot into which you inserted the wire lead. The wire lead should be securely attached inside the connector. You should be able to pull on the wire and not dislodge it. Warning. For DC input voltages, the positive (+) wire of the sourcing equipment, such as a battery or rectifier, must be connected to the positive (+) terminal of the OmniSwitch DC power supply and the negative (-) wire of the sourcing equipment must be connected to the negative (-) terminal of the OmniSwitch DC power supply." 5 Repeat Steps 2 through 4 for the remaining positive and negative wire leads. OS6850 Power Supply DC Power Source Correct Polarity Connections OmniSwitch 6850/6850E Series Hardware Users Guide June 2011 page 4-19