    PIKE 2108 LSISAS RAID card User Guide
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 2
    Product warranty or service will not be extended if: (1) the product is repaired, modified or altered, unless such repair, modification of alteration is authorized in writing by ASUS; or (2) the serial number of the product is defaced or missing. ASUS PROVIDES THIS MANUAL "AS IS" WITHOUT WARRANTY
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 3
    Contents About this guide v PIKE 2108 specifications summary vii Chapter 1: Product introduction 1.1 Welcome 1-2 1.2 Package contents 1-2 1.3 Card layout 1-3 1.4 System requirements 1-3 1.5 Card installation 1-4 Chapter 2: RAID configuration 2.1 Setting up RAID 2-2 2.1.1 RAID definitions
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 4
    Contents 3.3 Windows® Server 2008 OS Driver Installation 3-9 3.3.1 During Windows® Server 2008 OS installation 3-9 3.3.2 After Windows® Server 2008 OS installation 3-11 3.4 Red Hat® Enterprise Linux OS 5 Driver Installation 3-13 3.5 SUSE® Linux OS 11 Driver Installation 3-15 iv
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 5
    This chapter offers the PIKE 2108 SAS RAID card features and the new technologies it supports. • Chapter 2: RAID configuration This chapter provides instructions on setting up, creating, and configuring RAID sets using the available utilities. • Chapter 3: Driver installation This chapter provides
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 6
    the following symbols used throughout this manual. DANGER/WARNING: Information to prevent injury to yourself when trying to complete a task. CAUTION: Information to prevent damage to the components when trying to complete a task. IMPORTANT: Instructions that you MUST follow to complete
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 7
    PIKE 2108 specifications summary Controller Interface Ports Support Device Data transfer rate RAID level Cache Battery Backup Support OS support* Form factor LSI SAS 2108 6Gb/s SAS Controller ASUS PIKE interface 8 ports SAS / SAS II devices SATA / SATA II / SATA III devices SATA III and SAS II 6Gb
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 8
    viii
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 9
    This chapter offers the PIKE 2108 SAS RAID card features and the new technologies it supports. Chapter 1: 1Product introduction
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 10
    items in your package with the list below. 1.2 Package contents Check your package for the following items. ASUS PIKE 2108 SAS RAID card Heatsink for 5U/2U system Support CD User Guide BBU cable* SATA cable* Packing Quantity Standard Gift Box Pack 1 1 1 1 1 8 1 pc per carton Standard Bulk Pack
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 11
    BBU cable connector 1.4 System requirements Before you install the PIKE 2108 SAS RAID card, check if the system meets the following requirements: • Workstation or server motherboard with a PIKE RAID card slot • SAS or SATA hard disk drives • Supporting operating system: Windows® and Linux operating
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 12
    installation Follow the below instructions to install ASUS PIKE 2108 SAS RAID card to your server system. For 1U server, install the SAS RAID card to the PIKE RAID card slot on the motherboard. It is recommended to install a low-profile form factor PCIe expansion card with full height bracket, or
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 13
    Install ASUS PIKE 2108 SAS RAID card to the server system 1. Locate the PIKE RAID card slot on the motherboard. 2. Align the golden fingers of the RAID card with the PIKE RAID card slot. Insert the RAID card into the PIKE RAID card slot. Ensure the card is completely inserted into the card slot, and
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 14
    cable If you have a LSI Battery Backup Unit (BBU), connect the BBU cable to the BBU connector on the PIKE RAID card. Align the pin 1 wire (red) of the BBU cable to the triangle mark on the BBU connector, and then firmly insert the cable. Uninstall ASUS PIKE 2108 SAS RAID card from the server system
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 15
    This chapter provides instructions on setting up, creating, and configuring RAID sets using Chapcteornf2ig: urRa2tAioIDn the available utilities.
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 16
    2.1 Setting up RAID The RAID card supports RAID 0, 1, 10, 5, 50, 6, and 60. 2.1.1 RAID definitions RAID 0 (Data striping) of at least two new identical hard disk drives is required for this setup. RAID 1 (Data mirroring) copies and maintains an identical image of data from one drive to
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 17
    the SAS hard disks into the drive bays following the instructions in the system user guide. 2. Connect a SAS signal cable to the signal connector at the back of each drive and to the SAS connector on the motherboard. 3. Connect a power cable to the power connector on each drive. ASUS PIKE 2108 2-3
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 18
    WebBIOS Configuration Utility (CU) is an integrated RAID solution that allows you to create RAID 0, 1, 10, 5, 50, 6, and 60 sets from SATA/SATA II/SATA III/SAS/SAS II hard disk drives supported by the LSI SAS 2108 controller. You can also use the WebBIOS CU to do the following tasks: • Create drive
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 19
    0 Virtual Drive(s) handled by BIOS Press for WebBIOS or press for Preboot CLI _ 3. The Adapter Selection screen appears. If the system has multiple SAS adapters, select an adapter. 4. Click Start to continue. The main WebBIOS CU screen appears. ASUS PIKE 2108 2-5
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 20
    this icon to exit the WebBIOS CU program. Click this icon to display information about the WebBIOS CU version, bus number, and device number. 2-6 Chapter 2: RAID configuration
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 21
    on the controller. • Controller Properties: Select this to view the properties of the currently selected SAS controller. • Scan Devices: Select this to have the WebBIOS CU re-scan the physical and virtual Select this to exit the WebBIOS CU and continue with system boot. ASUS PIKE 2108 2-7
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 22
    how to use the WebBIOS CU Configuration Wizard to configure RAID arrays and virtual drives. The default settings of the configuration Configuration. 4. On the next screen, select a configuration mode: • Manual Configuration: Allows you to control all attributes of the new storage configuration
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 23
    RAID 0 configuration. 5. Click Next to continue. Using Automatic Configuration Follow these instructions to create a configuration with automatic configuration, either with or without redundancy: 1. When WebBIOS displays the proposed new configuration, review for the drive group. ASUS PIKE 2108 2-9
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 24
    to SPAN. 6. When finish, click Next. The Virtual Drive Definition screen appears, as shown in the right figure. You use this screen to select the RAID level, strip size, read policy, and other attributes for the new virtual drives. 7. Change the virtual drive options from the defaults listed on the
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 25
    in a transaction. This setting has to be used with a Battery Backup Unit (BBU). This is the default. • IO Policy: The IO Policy RAID 0 shown in the Configuration panel on the right. You may specify a smaller size if you want to create other virtual drives on the same drive group. ASUS PIKE 2108
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 26
    to save the configuration. 14. Click Yes at the prompt to start initialization. Using Manual Configuration: RAID 1 In RAID 1, the RAID controller duplicates all data from one drive to a second drive. RAID 1 provides complete data redundancy, but at the cost of doubling the required data storage
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 27
    size of the segment written to each disk in a RAID configuration. You can set the strip size up to the data in a transaction. This setting has to be used with a Battery Backup Unit (BBU). This is the default. • IO Policy: The IO Policy applies to Specify the drive cache policy: ASUS PIKE 2108 2-13
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 28
    configuration, click Yes at the prompt to save the configuration. 14. Click Yes at the prompt to start initialization. Using Manual Configuration: RAID 10 RAID 10, a combination of RAID 1 and RAID 0, has mirrored drives. It breaks up data into smaller blocks, then stripes the blocks of data to each
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 29
    When you select Manual Configuration and click RAID 10 drive group. In version 1.03 of the utility, the maximum size of the RAID 10 drive group is the sum total of the two RAID 1 drive groups. In version 1.1, the maximum size is the size of the smaller drive group multiplied by two. ASUS PIKE 2108
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 30
    of the virtual drive options: • RAID Level: The drop-down menu lists the possible RAID levels for the virtual drive. Select RAID 10. • Strip Size: The the data in a transaction. This setting has to be used with a Battery Backup Unit (BBU). This is the default. • IO Policy: The IO Policy applies to
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 31
    RAID controller uses the parity drive to recreate all missing information. You can use RAID 5 for office automation and online customer service that require fault tolerance. In addition, RAID 5 is good for any application that has high read request rates but low write request rates. ASUS PIKE 2108
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 32
    When you select Manual Configuration and click Next, the Drive Group Definition screen appears. When finish, click Next. The Virtual Drive Definition screen appears. You use this screen to select the RAID level, strip size, read policy, and other attributes for the new virtual drives. 7. Change the
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 33
    data in a transaction. This setting has to be used with a Battery Backup Unit (BBU). This is the default. • IO Policy: The IO Policy applies megabytes, or kilobytes. Normally, this would be the full size for RAID 5 shown in the Configuration panel on the right. You may specify ASUS PIKE 2108 2-19
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 34
    Yes at the prompt to save the configuration. 14. Click Yes at the prompt to start initialization. Using Manual Configuration: RAID 50 RAID 50 provides the features of both RAID 0 and RAID 5. RAID 50 uses both distributed parity and drive striping across multiple drive groups. It provides high data
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 35
    . When finish, click Next. The Virtual Drive Definition screen appears. You use this screen to select the RAID level, strip size, read policy, and other attributes for the new virtual drive(s). 13. If there are data in a transaction. This setting is recommended in Standard mode. ASUS PIKE 2108 2-21
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 36
    the data in a transaction. This setting has to be used with a Battery Backup Unit (BBU). This is the default. • IO Policy: The IO Policy applies to gigabytes, megabytes, or kilobytes. Normally, this would be the full size for RAID 50 shown in the Configuration panel on the right. You may specify a
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 37
    the size of the segment written to each disk in a RAID configuration. You can set the strip size up to 64 KB. A larger strip size produces higher read performance. If your computer regularly performs random read requests, choose a smaller strip size. The default is 64 KB. ASUS PIKE 2108 2-23
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 38
    has received all of the data in a transaction. This setting has to be used with a Battery Backup Unit (BBU). This is the default. • IO Policy: The IO Policy applies to reads on a specific drive cache. • Disable BGI: Specify the background initialization status: 2-24 Chapter 2: RAID configuration
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 39
    and medium to large capacity. When you select Manual Configuration and click Next, the Drive Group Definition screen appears. You use this screen to select drives to create drive groups. 1. Hold while selecting at least three ready drives in the Drives panel on the left. ASUS PIKE 2108 2-25
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 40
    undo the changes, click the Reclaim button. 4. Click Accept DG to create a RAID 6 drive group. An icon for a second drive group displays in the right panel Virtual Drive Definition screen appears. You use this screen to select the RAID level, strip size, read policy, and other attributes for the new
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 41
    has received all of the data in a transaction. This setting has to be used with a Battery Backup Unit (BBU). This is the default. • IO Policy: The IO Policy applies to reads on a specific virtual want to allow background initializations for configurations on this controller. ASUS PIKE 2108 2-27
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 42
    • Select Size: Specify the size of the virtual drive in terabytes, gigabytes, megabytes, or kilobytes. Normally, this would be the full size for RAID 60 shown in the Configuration panel on the right. You may specify a smaller size if you want to create other virtual drives on the same
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 43
    for controllers, virtual drives, and drives. WebBIOS allows you to view information for the LSI SAS controller. To view the properties for the controller, click Controller Properties on the main WebBIOS the best performance, unless you have a specific reason for changing them. ASUS PIKE 2108 2-29
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 44
    A cluster is a grouping of independent servers that can access the same data storage and provide services to a common set of clients. When Cluster mode is disabled, the system operates in Standard mode (S.M.A.R.T. error). The default is 300 seconds (5 minutes). 2-30 Chapter 2: RAID configuration
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 45
    might not be possible to use a boot device elsewhere. Schedule CC "Supported" will be displayed if the controller supports consistency check schedule. StopOnError Enable this option if you want the boot process mind, click Reset to return the options to their default values. ASUS PIKE 2108 2-31
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 46
    above vary with the existing RAID level. The Properties panel of this screen displays the virtual drive's RAID level, state, capacity, and drive. This works only if the drives are installed in a drive enclosure that supports SAFTE. • Select Fast or Slow to initialize this virtual drive. A fast
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 47
    list of drives. 2. Click Go. When the message appears, confirm that you want to migrate the RAID level of the virtual drive. A reconstruction operation begins on the virtual drive. You must wait until the drive expands by the selected percentage of the available capacity. ASUS PIKE 2108 2-33
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 48
    drive. This works only if the drive is installed in a drive enclosure. • Select Stop Locate to disable the LED flash on the drive. 2-34 Chapter 2: RAID configuration
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 49
    . • Select Make Unconf Bad to make the drive state to become Unconfigured Bad. • Select Prepare Removal to prepare the drive for removal from the enclosure. ASUS PIKE 2108 2-35
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 50
    2.2.5 Viewing System Event Information The SAS controller firmware monitors the activity and performance of all storage configurations and devices in the system. When an timestamp and a description to help you determine when the event occurred and what it was. 2-36 Chapter 2: RAID configuration
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 51
    -tolerant virtual drives. A consistency check verifies that the redundancy data is correct and available for RAID 1, RAID 5, and RAID 10 arrays. To do this, follow these steps: 1. On the main WebBIOS CU screen message appears, confirm that you want to delete the virtual drive. ASUS PIKE 2108 2-37
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 52
    foreign configuration by the RAID controller. The WebBIOS CU allows you to import the foreign configuration to the RAID controller, or to clear configuration: 1. Click the drop-down list to show the configurations. The GUID (Global Unique Identifier) entries on the drop-down list are OEM names and
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 53
    removal, for example, the configuration on those drives is considered a foreign configuration by the RAID controller. Use the Foreign Configuration Preview screen to import or clear the foreign configuration in rebuild is complete to ensure data integrity for the virtual drives. ASUS PIKE 2108 2-39
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 54
    clear the foreign configuration. No rebuilds will occur after the import operation because there is no redundant data to rebuild the drives with. 2-40 Chapter 2: RAID configuration
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 55
    to configure, monitor, and maintain storage configurations on LSI SAS controllers. The MegaRAID Storage Manager graphical user interface software on a system running Microsoft Windows OS: 1. Insert the ASUS PIKE 2108 Support CD in the optical disc drive. The CD automatically displays the Utilities
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 56
    , or click Change to select a different destination folder. Click Next to continue. The Setup Type screen appears, as shown in the following figure. 2-42 Chapter 2: RAID configuration
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 57
    workstation. To begin installation, click on Install on the next screen that appears. - Select Custom if you want to specify individual program features to install. ASUS PIKE 2108 2-43
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 58
    , as shown in the following figure. The server screen will not list any servers. You can use this screen to manage systems remotely. 2-44 Chapter 2: RAID configuration
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 59
    steps if you need to install MegaRAID Storage Manager software on a system running Red Hat Linux or SUSE Linux: 1. Copy the MSM_linux_installer...tar.gz file to a temporary folder. 2. Untar the not list any servers. You can use this screen to manage systems remotely. ASUS PIKE 2108 2-45
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 60
    you are installing MegaRAID Storage Manager software on a Linux system: • More than one copy of MegaRAID In such cases, the user must uninstall all the rpm files manually before installing MegaRAID Storage Manager software with the procedure listed previously. 2-46 Chapter 2: RAID configuration
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 61
    of programs that use Java.) - To start MegaRAID Storage Manager software on a Red Hat Linux system, select Applications > System Tools > MegaRAID Storage Manager StartupUI. - To start MegaRAID program starts, the select server window appears, as shown in the following figure. ASUS PIKE 2108 2-47
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 62
    mode. If your user name and password are correct for the Login mode you have chosen, the main MegaRAID Storage Manager window appears. 2-48 Chapter 2: RAID configuration
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 63
    in progress, MegaRAID Storage Manager features and their status (enabled or disabled), and actions you can perform, such as creating a virtual drive and updating the firmware, as shown in the following figure. ASUS PIKE 2108 2-49
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 64
    a device is running in a degraded state. For example, this icon indicates that a virtual drive is running in a degraded state because a drive has failed: . 2-50 Chapter 2: RAID configuration
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 65
    left panel, the Properties tab lists information such as the controller name, NVRAM size, and device port count. Event Log Panel The lower part of the MegaRAID Storage Manager window displays the system event delivery rules, event severity levels, exceptions, and email settings. ASUS PIKE 2108 2-51
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 66
    from showing active content. If this warning appears, click on the active content warning bar and enable the active content. • If you are using the Linux operating system, you must install Firefox® or Mozilla® for the MegaRAID Storage Manager online help to display. 2-52 Chapter
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 67
    This chapter provides instructions for installing the RAID drivers on different operating systems. Chapter 3: 3Driver installation
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 68
    part provides instructions on how to install or update the RAID card drivers. The RAID card driver might be included in the Linux OS installation CD, and could be loaded automatically during OS installation. However, we recommend using the RAID driver packaged in the RAID card support CD for better
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 69
    Use the arrow keys to select the type of RAID driver disk you want to create. PIKE 2108 SAS2 card Driver Windows XP 32 bit Windows XP 64 bit Windows , high-density floppy disk to the floppy disk drive. 8. Press . 9. Follow screen instructions to create the driver disk. ASUS PIKE 2108 3-3
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 70
    the RAID card driver when manually specify an adapter. Currently, Setup will load support for the following mass storage devices(s): * To specify additional SCSI adapters, CD-ROM drives, or special disk controllers for use with Windows, including those for which you have a device support
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 71
    Driver (Server 2003 32-bit) ENTER=Select F3=Exit 6. The Windows® Setup loads the RAID card drivers from the RAID driver disk. When next screen appears, press to continue installation. 7. Setup then proceeds with the OS installation. Follow screen instructions to continue. ASUS PIKE 2108
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 72
    My Computer and select Manage from the menu. 2. In the Computer Management window, click the Device Manager item. 3. Double-click RAID Controller under the Other Devices item. The controller name differs according to the installed SAS RAID card. 4. Click the Driver tab on the top, then click Update
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 73
    No, Not this time to cancel searching driver from Windows Update, and then click Next to continue. 6. Toggle Install from a list or specific location (Advanced), then click Next to continue. 7. Select the Include this location in the search: check box, and then click Browse. ASUS PIKE 2108 3-7
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 74
    SAS RAID card Support CD into the optical drive. 8. Locate the driver in the corresponding folder of the Support CD, and then click OK to continue. 9. The system automatically updates the driver. After completing driver update, click Finish to close the wizard. 3-8 Chapter 3: Driver installation
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 75
    to insert the installation media containing the driver of the SAS RAID card. If you have only one optical drive installed in your system, eject the Windows OS installation disc and replace with the PIKE SAS RAID card Support CD into the optical drive. Click Browse to continue. ASUS PIKE 2108 3-9
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 76
    Next. 7. When the system finishes loading the RAID driver, replace the SAS RAID card Support CD with the Windows Server installation disc. Select the drive to install Windows and click Next. 8. Setup then proceeds with the OS installation. Follow screen instructions to continue. 3-10 Chapter
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 77
    "+" sign before Diagnostics and click Device Manager. Click the "+" sign before Storage controllers, and double-click LSI MegaRAID SAS Adapter. The controller name differs according to the installed SAS RAID card. 4. Click the Driver tab on the top, then click Update Driver. ASUS PIKE 2108 3-11
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 78
    Browse my computer for driver software. 6. Insert the SAS RAID card Support CD into the optical drive. Click Browse. 7. In the Browse for Folder window, locate the driver in the corresponding folder of the Support CD, and then click OK to continue. 8. In the Update Driver Software window, click Next
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 79
    ? Yes No 4. Insert the Red Hat® Enterprise RAID driver disk to the USB floppy disk drive, select OK, then press . Insert Driver Disk Insert your driver disk into /dev/sda and press "OK" to continue. OK Back The drivers for the RAID card are installed to the system. ASUS PIKE 2108 3-13
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 80
    wish to load any more driver disks? Yes No 6. Select Skip and press to continue. CD Found To begin testing the CD media before installation press OK. Choose Skip to skip the media test and start the installation. OK Skip 7. Follow the screen instructions to continue the OS installation
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 81
    , select the USB floppy disk drive (sdx) as the driver update medium. Select OK, then press . Please choose the Driver Update medium. sda: USB Floppy sr0: CD-ROM, ASUS DRW-2014S1T Other device OK Back The drivers for the RAID controller are installed to the system. ASUS PIKE 2108 3-15
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 82
    3-16 Chapter 3: Driver installation
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 83
    , 40880 Ratingen, Germany Fax +49-2102-959911 Web site http://www.asus.de Online contact http://www.asus.de/sales Technical Support Telephone +49-1805-010923* Support Fax +49-2102-959911 Online support http://support.asus.com/techserv/techserv.aspx * EUR 0.14/minute from a German fixed
  • Asus PIKE 2108 | PIKE 2108 user's manual - Page 84
    112, TAIWAN R.O.C. Country: TAIWAN Authorized representative in Europe: ASUS COMPUTER GmbH Address, City: HARKORT STR. 21-23, 40880 RATINGEN Country: GERMANY declare the following apparatus: Product name : PIKE Card Model name : PIKE 2108 conform with the essential requirements of the
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84

LSISAS RAID card
PIKE 2108
User Guide