Asus PIKE 2108 PIKE 2108 user's manual - Page 50

Viewing System Event Information, Events, Enclosure - firmware

Page 50 highlights

2.2.5 Viewing System Event Information The SAS controller firmware monitors the activity and performance of all storage configurations and devices in the system. When an event occurs (such as the creation of a new virtual drive or the removal of a drive) an event message is generated and is stored in the controller NVRAM. You can use the WebBIOS CU to view these event messages. To do this, click Events on the main WebBIOS CU screen. The Event Information screen appears, as shown in the following figure. The right side of the screen is blank until you select an event to view. The First Sequence and Last Sequence fields in the upper left of the screen show you how many event entries are currently stored. To view event information, follow these steps: 1. Select an Event Locale from the menu. For example, select Enclosure to view events relating to the drive enclosure. 2. Select an Event Class: [Informational], [Warning], [Critical], [Fatal], or [Dead]. 3. Enter a Start Sequence number, between the First Sequence and Last Sequence numbers. The higher the number, the more recent the event. 4. Enter the Number of events of this type that you want to view, and click Go. The first event in the sequence appears in the right panel. 5. Click Next or Prev to page forward or backward through the sequence of events. 6. If you want, select different event criteria in the left panel, and click Go again to view a different sequence of events. Each event entry includes a timestamp and a description to help you determine when the event occurred and what it was. 2-36 Chapter 2: RAID configuration

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84

2-36
Chapter 2: RAID configuration
2.2.5
Viewing System Event Information
The SAS controller firmware monitors the activity and performance of all storage
configurations and devices in the system. When an event occurs (such as the
creation of a new virtual drive or the removal of a drive) an event message is
generated and is stored in the controller NVRAM. You can use the WebBIOS CU
to view these event messages. To do this, click
Events
on the main WebBIOS CU
screen. The Event Information screen appears, as shown in the following figure.
The right side of the screen is blank until you select an event to view. The First
Sequence and Last Sequence fields in the upper left of the screen show you how
many event entries are currently stored.
To view event information, follow these steps:
1.
Select an Event Locale from the menu. For example, select
Enclosure
to
view events relating to the drive enclosure.
2.
Select an Event Class: [Informational], [Warning], [Critical], [Fatal], or [Dead].
3.
Enter a Start Sequence number, between the First Sequence and Last
Sequence numbers. The higher the number, the more recent the event.
4.
Enter the Number of events of this type that you want to view, and click
Go
.
The first event in the sequence appears in the right panel.
5.
Click
Next
or
Prev
to page forward or backward through the sequence of
events.
6.
If you want, select different event criteria in the left panel, and click
Go
again
to view a different sequence of events.
Each event entry includes a timestamp and a description to help you
determine when the event occurred and what it was.