Brother International HE-800A Instruction Manual - English - Page 89
Changing Functions Using The Dip Switches
View all Brother International HE-800A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 89 highlights
13. CHANGING FUNCTIONS USING THE DIP SWITCHES 13. CHANGING FUNCTIONS USING THE DIP SWITCHES 13-1. Panel DIP switches Always turn off the power supply before changing any of the DIP switch settings. Any changes to the DIP switch positions will not be effective until the power is switched off and back on again. 3993Q Note: Move the switches properly. DIP switch A No. ON/OFF ON 1 OFF ON 2 OFF ON 3 OFF ON 4 OFF ON 5 OFF ON 6 OFF ON 7 OFF ON 8 OFF Setting items Work clamp remains lowered after sewing is complete (rises when treadle is depressed backward) Work clamp rises after sewing is complete Pausing enabled during automatic sewing when the treadle is depressed backward Pausing disabled during automatic sewing when the treadle is depressed backward Display setting during automatic mode = bobbin thread counter (Default: 100) Display setting during automatic mode = production counter (Default: 0) 2-cycle sewing ON (All programs will be set to 2-cycle sewing regardless of the setting for parameter No. 55.) 2-cycle sewing OFF Upper thread breakage detection disabled Upper thread breakage detection enabled Programs disabled Programs enabled Default OFF OFF OFF OFF OFF OFF OFF OFF 81 HE-800A