Brother International PT-9600 Service Manual - Page 88
Installing the KB Unit/Rubber Key Unit
UPC - 012502602774
View all Brother International PT-9600 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 88 highlights
[ 8 ] Installing the KB Unit/Rubber Key Unit (1) Secure the FG wire "A" to the back of the KB unit or rubber key unit with a screw (for U.S.A./CANADA spec. only). (2) Connect the jog PCB ASSY harness to the connector on the main PCB and lock it. (for EU spec. only) (3) Insert the FPC cable into the connector on the main PCB and lock it while holding the KB unit or rubber key unit up (for U.S.A./CANADA spec. only). (4) Hold the KB unit or rubber key unit while passing the FPC cable though the slit of the ferrite core and insert the harness to the connector on the main PCB (for EU spec. only). Note: Exchange the cushion of the ferrite core, if it is damaged. (5) Assemble the KB unit or rubber key unit to the bottom cover with the hooks in eight places until confirming click noise sounds. Note 1: Be sure not to catch the FG wire "A" between any hooks. Note 2: Ensure that no harness rides on the support lib of the jog PCB (for EU spec. only). Hooks KB unit Hooks FPC cable Bottom cover FG wire "A" (PT-9600/PT-3600 U.S.A./CANADA only) Bottom cover Hooks Jog PCB ASSY harness (for EU spec. only). Screw FG wire "A" (PT-9600/PT-3600 U.S.A./CANADA only) Ferrite core (for EU spec. only) Cushion (for EU spec. only) Fig. 3.2-41 Installing the KB Unit/Rubber Key Unit III-54