Drive unit
View all Canon 1692B002 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 107 highlights
Chapter 4 [1] [2] [2] [1] [2] F-4-22 m) Release lever Removing the release lever 1) To remove release lever [1], remove the purge unit and then remove the release lever. To do so, keep pinch roller [2] pressurized to ease to work of phase alignment during gear installation. Reinstalling the release lever 1) To install the release lever, align the gear of the release lever with mark [3] (phase) in the receiving gear. [2] [3] [1] F-4-23 4.3.5 Drive unit 0014-8962 a) Feed motor Removing the feed motor 1) To remove feed motor [1], loosen four screws [2] and remove timing belt [3] and spring [4]. 2) Remove four loosened screws [2] to release feed motor [1] and remove the connector. Reinstalling the feed motor To reassemble the feed roller drive timing belt [3] into position, set the tension of timing belt [3] by adjusting the pressure of spring [4]. Then, fix feed motor [1]. 4-11