Canon VB-S905F Network Camera VB-S30D/VB-S31D/VB-S800D/VB-S805D/VB-S900F/VB-S9 - Page 160
Application Memory Card Messages, C001 Starting and stopping of camera control module
View all Canon VB-S905F manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 160 highlights
V420 Could not start intelligent service [crit] Description intelligent initialization error [%1] [%2] . (V420) %1 Error number %2 Cause of error Meaning Failed to initialize intelligent service. Countermeasure If the problem persists after rebooting, the camera is faulty. Arrange for servicing. V421 Intelligent service error [crit] Description intelligent working error [%1] [%2] . (V421) %1 Error number %2 Cause of error Meaning An error that does not permit recovery occurred while intelligent service was running. Countermeasure If the problem persists after rebooting, the camera is faulty. Arrange for servicing. Application (Memory Card) Messages M001 Starting and stopping of memory card control module [info] Description %1 sdctrl (M001) %1 Starting or stopping Meaning The memory card control module (sdctrl) has started or stopped. M203 Not enough space on memory card [warning] Description There is not available space (M203) Meaning Insufficient memory card capacity. M204 Invalid file removed [warning] Description Invalid file %1 was removed. (M204) %1 Name of removed file Meaning An invalid file was removed. M207 Memory card removed before unmounting [warning] Description Memory card was pulled before unmount. (M207) Meaning The memory card was removed while still mounted. M208 Video file limit [warning] Description Video file count of %1 reached upper limit. (M208) %1 Video type ([Upload], [Recording-Mode Stream], [Manual], [Timer], [Event]) Meaning The upper limit for the number of video files that can be saved for that video type has been reached. Logs will be output for [Timer] and [Event] only when [Overwrite videos] is set to [Disable]. M301 Memory card control module error [err] Description %1 process failure (M301) %1 mount or unmount Meaning Mount or unmount process failed. Application (Camera) Messages C001 Starting and stopping of camera control module [info] Description %1 camerad (C001) %1 starting | stopping Meaning The camera control module started/ stopped. C002 Camera application started [info] Description starting cameraappl (C002) Meaning The camera application started. C201 Day/Night mode switching warning [warning] Description Can't switch Day/Night mode, because current mode is Auto. (C201) Meaning Could not switch day/night mode. Countermeasure Set Day/Night mode manually. C211 Camera control command overflow [warning] Description command queue overflowed (C211) Meaning The camera control command queue overflowed, and some commands were discarded. Countermeasure Allow a longer interval (200 ms) for sending the camera control command. 160