Cisco WS-C4003 Software Guide - Page 352
Power Consumption of Modules, Module, Power Consumed, During Operation, in Reset Mode
View all Cisco WS-C4003 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 352 highlights
Power Management Chapter 26 Administering the Switch This configuration requires 445W and cannot be used in 1+1 redundancy mode. Remember, when considering the 1+1 redundancy mode, you must carefully plan the configuration of the module power usage of your chassis. An incorrect configuration will momentary disrupt your system during the evaluation cycle. To avoid this disruption, carefully plan your configuration to ensure it is within the power limits, or return to the default 2+1 redundancy configuration by installing a third power supply in your switch and set the power budget to 2+1 redundancy mode. Use the set power budget 2 command to set the power budget to the 2+1 redundancy mode. Power Consumption of Modules A single power supply provides 400W; two power supplies provide 750W. When operational, the supervisor engines consume no more than 110W and the fan box consumes 25W. For power consumption of common Catalyst 4006 modules, see Table 26-1. Note Enter the show environment power command to display the current power budget and the current system power usage. Table 26-1 Power Consumption for Catalyst 4006 Modules Module Power Consumed Power Consumed During Operation in Reset Mode (W) (W) 6-port 1000BASE-X (GBIC) Gigabit Ethernet WS-X4306-GB 35 30 32-port 10/100 Fast Ethernet RJ-45 WS-X4232-RJ-XX 55 35 Catalyst 4000 Access Gateway Module with IP/FW IOS 120 60 WS-X4604-GWY 24-port 100BASE-FX Fast Ethernet switching module WS-X4124-FX-MT 90 75 32-port 10/100 Fast Ethernet RJ-45, plus 2-port 1000BASE-X (GBIC) Gigabit Ethernet 50 35 WS-4232-GB-RJ 48-port 100BASE-FX Fast Ethernet switching module WS-4148-FX-MT 120 10 18-port server switching 1000BASE-X (GBIC) Gigabit Ethernet 80 50 WS-4418-GB Catalyst 4006 Backplane Channel Module WS-X4019 10 10 48-port 10/100 Fast Ethernet RJ-45 WS-X4148-RJ 65 40 Catalyst 4003 and 4006 Layer 3 Services Module WS-X4232-L3 120 70 26-14 Software Configuration Guide-Catalyst 4000 Family, Catalyst 2948G, Catalyst 2980G, Releases 6.3 and 6.4 78-12647-02