4 Configuration D-Link 10 Gigabit Ethernet Switch User Manual Flow Control: Select to either turn flow control On or Off here. Ports configured for full-duplex use 802.3x flow control, half-duplex ports use back-pressure flow control, and Auto ports use an automatic selection of the two. Duplex: Select the duplex mode used here. Options to choose from are Auto, and Full. Speed: Select the port speed option here. This option will manually force the connected on the selected port to only connect at the speed specified here. Options to choose from are Auto, 100M, 1000M, 1000M Master, 1000M Slave, and 10G. The Switch allows users to configure two types of gigabit connections; 1000M Master and 1000M Slave which refer to connections running a 1000BASE-T cable for connection between the Switch port and another device capable of a gigabit connection. The master setting (1000M Master) will allow the port to advertise capabilities related to duplex, speed and physical layer type. The master setting will also determine the master and slave relationship between the two connected physical layers. This relationship is necessary for establishing the timing control between the two physical layers. The timing control is set on a master physical layer by a local source. The slave setting (1000M Slave) uses loop timing, where the timing comes from a data stream received from the master. If one connection is set for 1000M Master, the other side of the connection must be set for 1000M Slave. Any other configuration will result in a link down status for both ports. Capability Advertised: When the Speed is set to Auto and the copper port is selected, these capabilities are advertised during auto-negotiation. Description: Enter a 64 characters description for the corresponding port here. Click Apply to accept the changes made. System > Port Configuration > Port Status This window is used to view the Switch's physical port status and settings. Figure 4.31 - System > Port Configuration > Port Status System > Port Configuration > Error Disable Settings This window is used to configure the sending of SNMP notifications for error disable state. 31

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121

4 Configuration
D-Link 10 Gigabit Ethernet Switch User Manual
31
Flow Control:
Select to either turn flow control
On
or
Off
here. Ports configured for full-duplex use 802.3x
flow control, half-duplex ports use back-pressure flow control, and Auto ports use an automatic selection of
the two.
Duplex:
Select the duplex mode used here. Options to choose from are
Auto
, and
Full
.
Speed:
Select the port speed option here. This option will manually force the connected on the selected port
to only connect at the speed specified here. Options to choose from are
Auto
,
100M
,
1000M
,
1000M Master
,
1000M Slave
, and
10G
. The Switch allows users to configure two types of gigabit connections;
1000M
Master
and
1000M Slave
which refer to connections running a 1000BASE-T cable for connection between
the Switch port and another device capable of a gigabit connection. The master setting (1000M Master) will
allow the port to advertise capabilities related to duplex, speed and physical layer type. The master setting
will also determine the master and slave relationship between the two connected physical layers. This
relationship is necessary for establishing the timing control between the two physical layers. The timing
control is set on a master physical layer by a local source. The slave setting (1000M Slave) uses loop timing,
where the timing comes from a data stream received from the master. If one connection is set for 1000M
Master, the other side of the connection must be set for 1000M Slave. Any other configuration will result in a
link down status for both ports.
Capability Advertised:
When the Speed is set to
Auto
and the copper port is selected, these capabilities
are advertised during auto-negotiation.
Description:
Enter a 64 characters description for the corresponding port here.
Click
Apply
to accept the changes made.
System > Port Configuration > Port Status
This window is used to view the Switch’s physical port status and settings.
Figure 4.31 – System > Port Configuration > Port Status
System > Port Configuration > Error Disable Settings
This window is used to configure the sending of SNMP notifications for error disable state.