Dell Force10 S55T Installing the S55 System - Page 37
S55 Specifications, Chassis Physical Design, Environmental Parameters, AC Power Requirements
View all Dell Force10 S55T manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 37 highlights
S55 Specifications This chapter contains these major sections: • Chassis Physical Design • Agency Compliance Chassis Physical Design Parameter Height Width Depth Chassis weight with factory-installed components Rack clearance required Thermal Dissipation Power Consumption Specifications 1.73 inches (4.4 cm) 17.32 inches (44.0 cm) 18.74 inches (47.6cm) 14.41 pounds (approx.) (6.54 kg) Front: 5-inches (12.7 cm) Rear: 5-inches (12.7 cm) 461 BTU/hr (135W) 115 Watts (nominal) 135 Watts (maximum) Environmental Parameters Parameter Temperature Maximum altitude Relative humidity Shock Specifications 32° to 104°F (0° to 40°C) -40° to 158°F (-40° to 70°C) No performance degradation to 10,000 feet (3,048 meters) 10 to 85% non-condensing MIL-STD-810 AC Power Requirements Parameter Nominal Input Voltage Maximum AC Power Supply Input Current Maximum System Power Input Specifications 100 to 240 VAC, 47-63 Hz 5 A 135 W 8 S55 Specifications | 37