Page 14 highlights
Amigopod and ArubaOS Integration Application Note Modify NAS ID for Master Local Deployments In an Aruba master local deployment, you must modify the NAS ID of the local controllers to ensure that the correct identifier is recorded in the RADIUS accounting traffic sourced from each local controller that is responsible terminating the APs. In the VRD campus topology, the local controllers are deployed on the 10.169.145.0/24 network (VLAN 145). This network is used to send the RADIUS transactions toward the Amigopod deployed on 10.169.130.50. Data center AirWave Amigopod Master active Master standby File POS PBX RADIUS Internet Local mobility controller Local mobility controller arun_0279 Air monitor Based on the VLAN numbering in the VRD Local Controller deployment, the following modifications are recommended: Set the local controller NAS IP to the IP address on VLAN 145. Define the source interface for RADIUS traffic to use VLAN 145 also. These configuration changes must be performed on each local controller using the local interface of the controller. Aruba Networks, Inc. ArubaOS Configuration | 14