Dell PowerEdge 1655MC Replacing the Server Module Board - Page 22
Programming the Service Tag
View all Dell PowerEdge 1655MC manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 22 highlights
www.dell.com | support.dell.com Programming the Service Tag NOTE: The service tag is automatically written to a server module that is replaced in the field. This procedure is required only if, for some reason, the service tag is not programmed or is programmed incorrectly. 1 Connect a null modem cable to the server management module. 2 Open a HyperTerminal session with the following settings: • Set Bits per second to 115200 (default). • Set Data bits to 8. • Set Parity to None. • Set Stop bits to 1. • Set Flow control to HW. 3 Log into the server management module (ERA/MC) and type the following commands: racadm setsvctag -m server-x PE1655MC where x is the slot number of the server module you are updating and is the valid seven-digit service tag of the server module. For example, the command for server module number 2 with a service tag of 1234567 is as follows: racadm setsvctag -m server-2 PE1655MC 1234567 1-18 Replacing the Server Module Board