Dell PowerEdge C5230 Using the Baseboard Management Controller - Page 44
OEM' or System, Event Filter Tab
View all Dell PowerEdge C5230 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 44 highlights
Event Filter Tab A PEF implementation is recommended to provide at least 16 entries in the event filter table. A subset of these entries should be pre-configured for common system failure events, such as over-temperature, power system failure, fan failure events, etc. Remaining entries can be made available for 'OEM' or System Management Software configured events. Note that individual entries can be tagged as being reserved for system use - so this ratio of pre-configured entries to run-time configurable entries can be reallocated if necessary. The fields of PEF Management - Event Filter Tab are explained below. This page contains the list of configured PEF's. Table 1-21. PEF Management - Event Filter Item PEF ID Filter configuration Event Filter Action Sensor Name Add Modify Cancel Description This field displays the ID for the newly configured PEF entry (read-only). Check box to enable the PEF settings. Check box to enable PEF Alert action. This is a mandatory field. To choose the particular sensor from the sensor list. To add the new event filter entry and return to Event filter list. To modify the existing entries. To cancel the modification and return to Event filter list. 42