Dell PowerEdge R660 PowerEdge RAID Controller S160 Users Guide - Page 13

Physical disk write cache policy for SATA drives, Linux RAID, Drives, S160 operating system driver

Page 13 highlights

Drives Intel P5500/P5600 Kioxia CM6/CD6 Intel P5800x Hynix PE8010 SAMSUNG PM9A3 Samsung PM 1733a/ PM1735a Intel 5520/5620 Kioxia CD7 S160 operating system driver 7.0.0.0012 7.0.0.0012 7.0.0.0012 7.0.0.0012 7.0.0.0012 7.0.0.0012 7.0.0.0012 7.0.0.0012 S160 UEFI driver 7.0.0.0011 7.0.0.0011 7.0.0.0011 7.0.0.0011 7.0.0.0011 7.0.0.0011 7.0.0.0011 7.0.0.0011 NOTE: Hot removal or hot insertion of the NVMe PCIe SSDs in UEFI or pre-boot mode is not supported. In the operating system environment, hot-swapping two or more NVMe PCIe SSDs simultaneously is not supported. NOTE: Mixing of SATA drives and NVMe PCIe SSDs in a virtual disk is not supported. NOTE: Ensure that you use only the S160 UEFI configuration utility to configure the NVMe PCIe SSDs during preboot. NOTE: RAID configuration and boot from NVMe virtual disk is supported only in UEFI boot mode. NOTE: RAID configuration using Option ROM (OPROM) is not supported on systems with the NVMe PCIe SSD. Physical disk write cache policy for SATA drives The physical disk write cache policy feature enables the disk to cache the data first, and then the cached data is written to the storage device in the background. For more information about managing the physical disk write cache policy, see Managing the physical disk write cache policy for SATA drives. NOTE: You can use UEFI or Option ROM (OPROM) to configure the physical disk write cache policy. NOTE: You cannot configure a physical disk write cache policy on a non-RAID disk. NOTE: Linux RAID does not support configuring physical disk write cache policy, or virtual disk write cache policy. Linux RAID Linux operating systems supported: ● Red Hat Enterprise Linux 8.0 and above ● SUSE Linux Enterprise Server version 15 SP1 and above The Linux RAID feature is supported on all Sirius PowerEdge systems. You can use Linux RAID to protect data across multiple devices. The S160 configuration utility supports configuring RAID 1 virtual disk in UEFI mode. The Linux operating system can be installed on that virtual disk, and once the system boots to the Linux environment, the Linux native RAID driver manages the virtual disk. For information about configuring Linux RAID, see Configuring Linux RAID. NOTE: Ensure that your system has the latest BIOS firmware. You can download the latest BIOS firmware from https:// www.dell.com/support. NOTE: Ensure that you use only the S160 UEFI configuration utility to configure Linux RAID feature during pre-boot. NOTE: Ensure that the boot virtual disks are configured in RAID 1, using two physical disks of identical drive type (HDD or SSD) and sector size. However, you can also configure nonboot virtual disks in any of the supported RAID levels in the Linux operating system. Physical Disks 13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51

Drives
S160 operating system driver
S160 UEFI driver
Intel P5500/P5600
7.0.0.0012
7.0.0.0011
Kioxia CM6/CD6
7.0.0.0012
7.0.0.0011
Intel P5800x
7.0.0.0012
7.0.0.0011
Hynix PE8010
7.0.0.0012
7.0.0.0011
SAMSUNG PM9A3
7.0.0.0012
7.0.0.0011
Samsung PM 1733a/ PM1735a
7.0.0.0012
7.0.0.0011
Intel 5520/5620
7.0.0.0012
7.0.0.0011
Kioxia CD7
7.0.0.0012
7.0.0.0011
NOTE:
Hot removal or hot insertion of the NVMe PCIe SSDs in UEFI or pre-boot mode is not supported. In the operating
system environment, hot-swapping two or more NVMe PCIe SSDs simultaneously is not supported.
NOTE:
Mixing of SATA drives and NVMe PCIe SSDs in a virtual disk is not supported.
NOTE:
Ensure that you use only the S160 UEFI configuration utility to configure the NVMe PCIe SSDs during preboot.
NOTE:
RAID configuration and boot from NVMe virtual disk is supported only in UEFI boot mode.
NOTE:
RAID configuration using Option ROM (OPROM) is not supported on systems with the NVMe PCIe SSD.
Physical disk write cache policy for SATA drives
The physical disk write cache policy feature enables the disk to cache the data first, and then the cached data is written to the
storage device in the background. For more information about managing the physical disk write cache policy, see
Managing the
physical disk write cache policy for SATA drives
.
NOTE:
You can use UEFI or Option ROM (OPROM) to configure the physical disk write cache policy.
NOTE:
You cannot configure a physical disk write cache policy on a non-RAID disk.
NOTE:
Linux RAID does not support configuring physical disk write cache policy, or virtual disk write cache policy.
Linux RAID
Linux operating systems supported:
Red Hat Enterprise Linux 8.0 and above
SUSE Linux Enterprise Server version 15 SP1 and above
The Linux RAID feature is supported on all Sirius PowerEdge systems. You can use Linux RAID to protect data across multiple
devices. The S160 configuration utility supports configuring RAID 1 virtual disk in UEFI mode. The Linux operating system can
be installed on that virtual disk, and once the system boots to the Linux environment, the Linux native RAID driver manages the
virtual disk. For information about configuring Linux RAID, see
Configuring Linux RAID
.
NOTE:
Ensure that your system has the latest BIOS firmware. You can download the latest BIOS firmware from
https://
www.dell.com/support
.
NOTE:
Ensure that you use only the S160 UEFI configuration utility to configure Linux RAID feature during pre-boot.
NOTE:
Ensure that the boot virtual disks are configured in RAID 1, using two physical disks of identical drive type (HDD or
SSD) and sector size. However, you can also configure nonboot virtual disks in any of the supported RAID levels in the Linux
operating system.
Physical Disks