Dell PowerEdge R660 PowerEdge RAID Controller S160 Users Guide - Page 40

WARNING- Found virtual disks that are degraded, BIOS Configuration Utility <Ctrl><R&gt

Page 40 highlights

WARNING- Found virtual disks that are degraded This warning message is displayed when at least one virtual disk is in a Degraded state and Pause if Degraded is set to ON at the BIOS Configuration Utility Ctrl+R. The following message is displayed after the warning is displayed: --- Press Enter to continue, or Ctrl+R to enter setup ---. Press Enter to allow the operating system to continue with the boot sequence, or press Ctrl+R to enter into the BIOS Configuration Utility Ctrl+R to investigate the cause of the Degraded virtual disk. To investigate the cause, check for the following: ● Whether a physical disk in the virtual disk has failed or has gone offline. Check the status at the Physical Disks field. A Degraded status depends on the RAID level of the virtual disk and the number of physical disks that have failed: -For a virtual disk at RAID 1 or RAID 5, a single physical disk failure causes a Degraded status. -For a virtual disk at RAID 10, the failure of a physical disk in each of the mirror sets creates a Degraded status for the RAID 10. The failure of two physical disks in the same mirror set creates a Failed status for the RAID 10. ● Whether the controller has failed due to a firmware failure or a component failure. A failed controller causes a virtual disk not to boot. For the virtual disk to recover from Degraded status, the failed physical disk must be replaced and the virtual disk must be rebuilt using OpenManage Server Administrator Storage Management. When the rebuild operation is completed, the virtual disk status changes from Degraded to Ready. For a description of the rebuild function, see Storage Management at https:// www.dell.com/manuals. WARNING - Found virtual disks that are failed This warning message is displayed when at least one virtual disk is in a Failed state and Pause if Failed is set to ON at the BIOS Configuration Utility (). The following message is displayed after the warning is displayed: --- Press to continue, or to enter setup --- . Press to allow the operating system to continue its boot, or press to enter into the BIOS Configuration Utility () to investigate the cause of the Failed virtual disk. NOTE: A boot virtual disk that is in a Failed state prevents the operating system from booting. To investigate the cause, check for the following: ● Determine if a single or multiple physical disks in a non-redundant virtual disk have failed. If yes, data is lost. Recover the lost data from a backup storage source. ● Determine if two or more physical disks in a redundant virtual disk have failed. If yes, data is lost. Recover the lost data from a backup storage source. NOTE: For a RAID 10 configuration, if a single physical disk fails in each mirrored set, the redundant virtual disk goes to a Degraded status but data is not lost. If two physical disks fail in one of the mirrored sets, the redundant virtual disk goes to a Failed status and data is lost. WARNING - Found virtual disks that are degraded and failed This warning message is displayed when multiple virtual disks are in Degraded and Failed state and Pause if Degraded or Pause if Failed are set to ON at the BIOS Configuration Utility Ctrl+R. The following message is displayed after the warning is displayed: --- Press Enter to continue, or Ctrl+R to enter setup --- . Press to allow the operating system to continue its boot, or press Ctrl+R to enter into the BIOS Configuration Utility Ctrl+R to investigate the cause of the Degraded and Failed virtual disks. NOTE: A boot virtual disk that is in a Failed state prevents the operating system from booting. To investigate the cause, check for the following: 40 Troubleshooting your system

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51

WARNING- Found virtual disks that are degraded
This warning message is displayed when at least one virtual disk is in a
Degraded
state and
Pause if Degraded
is set to
ON
at
the
BIOS Configuration Utility Ctrl+R
.
The following message is displayed after the warning is displayed:
--- Press Enter to continue, or Ctrl+R to
enter setup ---
.
Press Enter to allow the operating system to continue with the boot sequence, or press Ctrl+R to enter into the
BIOS
Configuration Utility Ctrl+R
to investigate the cause of the
Degraded
virtual disk.
To investigate the cause, check for the following:
Whether a physical disk in the virtual disk has failed or has gone offline. Check the status at the
Physical Disks
field. A
Degraded
status depends on the RAID level of the virtual disk and the number of physical disks that have failed:
–For a virtual disk at RAID 1 or RAID 5, a single physical disk failure causes a
Degraded
status.
–For a virtual disk at RAID 10, the failure of a physical disk in each of the mirror sets creates a
Degraded
status for the RAID
10. The failure of two physical disks in the same mirror set creates a
Failed
status for the RAID 10.
Whether the controller has failed due to a firmware failure or a component failure. A failed controller causes a virtual disk not
to boot.
For the virtual disk to recover from
Degraded
status, the failed physical disk must be replaced and the virtual disk must be
rebuilt using OpenManage Server Administrator Storage Management. When the rebuild operation is completed, the virtual
disk status changes from
Degraded
to
Ready
. For a description of the rebuild function, see Storage Management at
https://
www.dell.com/manuals
.
WARNING - Found virtual disks that are failed
This warning message is displayed when at least one virtual disk is in a
Failed
state and
Pause if Failed
is set to
ON
at the
BIOS Configuration Utility (<Ctrl><R>)
.
The following message is displayed after the warning is displayed:
--- Press <Enter> to continue, or <Ctrl><R>
to enter setup ---
.
Press <Enter> to allow the operating system to continue its boot, or press <Ctrl><R> to enter into the
BIOS Configuration
Utility (<Ctrl><R>)
to investigate the cause of the
Failed
virtual disk.
NOTE:
A boot virtual disk that is in a
Failed
state prevents the operating system from booting.
To investigate the cause, check for the following:
Determine if a single or multiple physical disks in a non-redundant virtual disk have failed. If
yes
, data is lost. Recover the lost
data from a backup storage source.
Determine if two or more physical disks in a redundant virtual disk have failed. If
yes
, data is lost. Recover the lost data from
a backup storage source.
NOTE:
For a RAID 10 configuration, if a single physical disk fails in each mirrored set, the redundant virtual disk goes to a
Degraded
status but data is not lost. If two physical disks fail in one of the mirrored sets, the redundant virtual disk goes to
a
Failed
status and data is lost.
WARNING - Found virtual disks that are degraded and failed
This warning message is displayed when multiple virtual disks are in
Degraded
and
Failed
state and
Pause if Degraded
or
Pause if Failed
are set to
ON
at the
BIOS Configuration Utility Ctrl+R
.
The following message is displayed after the warning is displayed:
--- Press Enter to continue, or Ctrl+R to
enter setup ---
.
Press <Enter> to allow the operating system to continue its boot, or press Ctrl+R to enter into the
BIOS Configuration Utility
Ctrl+R
to investigate the cause of the
Degraded
and
Failed
virtual disks.
NOTE:
A boot virtual disk that is in a
Failed
state prevents the operating system from booting.
To investigate the cause, check for the following:
40