E1210 CMOS Batt, E1211 ROMB Batt, E1229 CPU # VCORE, E1313 Fan, Redundancy, E1410 CPU # IERR
View all Dell PowerEdge R900 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 24 highlights
Table 1-5. LCD Status Messages Code Test Causes Corrective Actions E1210 CMOS Batt CMOS battery is missing, See "Troubleshooting the or the voltage is out of System Battery" on acceptable range. page 136. E1211 ROMB Batt RAID battery is either missing, bad, or unable to recharge due to thermal issues. Reseat the RAID battery connector. See "Installing a RAID Battery" on page 84, and "Troubleshooting the System Battery" on page 136. E1229 CPU # VCORE Processor # VCORE See "Getting Help" on voltage regulator has failed. page 165. E1310 RPM Fan ## RPM of specified cooling fan is out of acceptable operating range. See "Troubleshooting System Cooling" on page 138. E1313 Fan Redundancy The system is no longer fan-redundant. Another fan failure will put the system at risk of overheating. Check control panel LCD for additional scrolling messages. See "Troubleshooting System Cooling" on page 138. E1410 CPU # IERR Specified microprocessor is See your system's reporting an internal error. Information Update Tech Sheet located on support.dell.com for the most current system information. If problem persists, see "Getting Help" on page 165. 24 About Your System