Dell PowerEdge R900 Hardware Owner's Manual (PDF) - Page 29
E1A14 SAS Cable - firmware
View all Dell PowerEdge R900 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 29 highlights
Table 1-5. LCD Status Messages Code Test Causes Corrective Actions E1811 HDD ## Rbld Abrt The specified hard drive has experienced a rebuild abort. See "Troubleshooting a Hard Drive" on page 142. If the problem persists, see your RAID documentation. E1812 HDD ## Removed The specified hard drive Information only. has been removed from the system. E1913 CPU & Firmware Mismatch The BMC firmware does not support the processor. Update to the latest BMC firmware. See the BMC User's Guide for more information on setup and use of BMC. E1A14 SAS Cable A SAS cable A is missing or bad. Reseat the cable. If problem persists, replace cable. See "SAS Controller Card" on page 78. E1A15 SAS Cable B SAS cable B is missing or bad. Reseat the cable. If problem persists, replace cable. See "SAS Controller Card" on page 78. E2010 No Memory No memory is installed in the system. Install memory. See "General Memory Module Installation Guidelines" on page 92. E2011 Mem Config Error Memory detected, but is not configurable. Error detected during memory configuration. See "Troubleshooting System Memory" on page 139. E2012 Unusable Memory Memory is configured, but See "Troubleshooting not usable. Memory System Memory" on subsystem failure. page 139. E2013 Shadow BIOS The system BIOS failed to See "Troubleshooting Fail copy its flash image into System Memory" on memory. page 139. About Your System 29