Dell PowerEdge T710 Hardware Owner's Manual - Page 27
E122D Memory, E122E On-board
View all Dell PowerEdge T710 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 27 highlights
Table 1-1. LCD Status Messages (continued) Code Text Causes Corrective Actions E122A CPU # VTT Regulator failure. Reseat CPU. Specified processor VTT voltage regulator has failed. Reseat the processor(s). See "Troubleshooting the Processors" on page 179. If the problem persists, see "Getting Help" on page 193. E122C CPU Power Fault. Power cycle AC. A power fault was detected when powering up the processor(s). Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 193. E122D Memory Regulator # One of the memory regulators has failed. Failed. Reseat DIMMs. Reseat the memory modules. See "Troubleshooting System Memory" on page 167. E122E On-board regulator failed. Call support. One of the on-board voltage regulators failed. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 193. E1310 Fan ## RPM exceeding range. Check fan. RPM of the specified fan See "Troubleshooting is outside of the intended System Cooling operating range. Problems" on page 166. E1311 Fan module ## RPM exceeding range. Check fan. RPM of the specified fan in a specified module is outside of intended operating range. See "Troubleshooting System Cooling Problems" on page 166. E1313 Fan redundancy The system is no longer lost. Check fan redundant. Another fans. fan failure would put the system at risk of over- heating. Check LCD for additional scrolling messages. See "Troubleshooting a Fan" on page 166. About Your System 27