Dell S3048-ON EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 9
Topology
View all Dell S3048-ON manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 9 highlights
3 Topology S2D clusters are limited to 16 nodes. In this deployment, four S2D Ready Nodes are installed in a single rack along with two leaf switches and one OOB management switch. The devices are cabled as shown in Figure 5. S3048-ON OOB Mgmt S5248F-ON Leaf 1A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 Stack ID S5248F-ON Leaf 1B R640 Management System R740xd S2D Ready Node 1 GRN =10G ACT/ LNK A GRN =10G ACT/ LNK B Stack ID 1 2 iDRAC 1 3 750W 750W GRN =10G ACT/ LNK A GRN =10G ACT/ LNK B R740xd S2D Ready Node 2 GRN =10G ACT/ LNK A GRN =10G ACT/ LNK B R740xd S2D Ready Node 3 GRN =10G ACT/ LNK A GRN =10G ACT/ LNK B R740xd S2D Ready Node 4 25GbE Storage traffic 10GbE In-band mgmt and VM traffic 2x100GbE VLTi (QSFP28-DD DAC) 1GbE OOB mgmt All cabling for the S2D environment 9 Dell EMC Solutions for Microsoft Azure Stack HCI Networking Guide