Dell S5232F-ON EMC Networking OS10 Enterprise Edition Deployment Guide with Ci - Page 15
Cisco APIC configuration, VLAN name, Gateway IP, address/mask, Bridge domain name
View all Dell S5232F-ON manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 15 highlights
6 Cisco APIC configuration The Cisco APIC configuration includes the ports that are connected to the R730xd rack servers and the vPC that connects to the S5248F-ON VLT port channel. Included are the configuration of the ACI fabric interfaces, switches, and application-level elements such as ACI endpoint groups (EPGs) and bridge domains. The networks that are used in the validated environment are shown in Table 5, along with the corresponding bridge domain, and application EPG names used in APIC configuration. VLAN ID 1612 1613 1614 1615 1616 Validated environment network information VLAN name Gateway IP address/mask Bridge domain name vMotion 172.16.12.254/24 vMotionBD1 vSAN 172.16.13.254/24 vSANBD1 web 172.16.14.254/24 webBD1 app 172.16.15.254/24 appBD1 db 172.16.16.254/24 dbBD1 Application EPG name vMotionEPG1 vSANEPG1 webEPG1 appEPG1 dbEPG1 In this deployment, EPGs are extended outside of the ACI fabric by mapping EPGs to external VLANs. This is so when a frame tagged with VLAN 1611, for example, enters the ACI fabric, ACI knows that it belongs to the ESXi Management EPG and treats it accordingly. Bridge domains are associated with EPGs, which are mapped to external VLANs. 15 Dell EMC Networking OS10 Enterprise Edition Deployment Guide with Cisco ACI