Dell S5232F-ON EMC Networking OS10 Enterprise Edition Deployment Guide with Ci - Page 28
Verify physical interface configuration, Fabric > Inventory > Pod 1 >
View all Dell S5232F-ON manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 28 highlights
9.2.2 Verify physical interface configuration The physical, host-connected, interfaces in the validated environment are those connected directly to the PowerEdge R730xd servers as shown in Figure 6. Verify the physical interfaces from the Cisco ACI fabric to the servers are up and properly configured to enable designated VLANs and EPGs. This configuration is done as follows: 1. In the APIC GUI, go to Fabric > Inventory > Pod 1 > Leaf name > Interfaces > Physical Interfaces as shown in Figure 14. Cisco ACI physical interfaces 2. Verify all required interfaces, for example, eth1/1-2, are up. 3. With an interface selected in the left pane, click VLANs at the top of the right pane as shown in Figure 13. Cisco ACI interface VLANs and EPGs 28 Dell EMC Networking OS10 Enterprise Edition Deployment Guide with Cisco ACI