Dell S5232F-ON EMC Networking OS10 Enterprise Edition Deployment Guide with Ci - Page 20
Switch pair uplink configuration
View all Dell S5232F-ON manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 20 highlights
7.5 Switch pair uplink configuration Configure the VLT port channel and interfaces connecting to the ACI leaf switches. Configure and enable uplink failure detection (UFD). Uplink configuration S5248F-1 S5248F-2 interface port-channel 100 interface port-channel 100 description "ACI connection" description "ACI connection" no shutdown no shutdown switchport mode trunk switchport mode trunk switchport access vlan 1 switchport access vlan 1 switchport trunk allowed vlan 1612-1616 switchport trunk allowed vlan 1612-1616 vlt-port-channel 100 vlt-port-channel 100 interface ethernet 1/1/55 description "ACI connection leaf 1 eth 1/1" no shutdown channel-group 100 mode active no switchport interface ethernet 1/1/55 description "ACI connection leaf 1 eth 1/2" no shutdown channel-group 100 mode active no switchport interface ethernet 1/1/56 description "ACI connection leaf 2 eth 1/1" no shutdown channel-group 100 mode active no switchport interface ethernet 1/1/56 description "ACI connection leaf 2 eth 1/2" no shutdown channel-group 100 mode active no switchport uplink-state-group 1 enable downstream ethernet1/1/3-1/1/4 upstream port-channel 100 uplink-state-group 1 enable downstream ethernet1/1/3-1/1/4 upstream port-channel 100 Note: UFD is a feature that disables downlink interfaces due to uplink interface failures. Configuration of UFD is a best practice to prevent downstream resources from sending traffic to a switch with failed uplinks. 20 Dell EMC Networking OS10 Enterprise Edition Deployment Guide with Cisco ACI