Dell S5232F-ON EMC Networking OS10 Enterprise Edition Deployment Guide with Ci - Page 17

Con S5248F-ON switches, 7.1 OOB management configuration, 7.2 VLT configuration

Page 17 highlights

7 7.1 Configure S5248F-ON switches The following section outlines the configuration commands that are issued to the Dell EMC Networking S5248F-ON ToR switches. OOB management configuration The OOB port for the Dell EMC Networking S5248F-ON is mgmt 1/1/1. The following commands show how to configure this OOB port when using OS10EE. The switches start at their factory default settings as described in Appendix A.1. Note: The S5248F-ON CLI is accessible through the console port or by using SSH. The default username and password are both admin. OOB management configuration S5248F-1 configure terminal S5248F-2 configure terminal hostname S5248F-1 hostname S5248F-2 interface mgmt 1/1/1 no ip address dhcp no shutdown ip address 100.67.166.33/24 interface mgmt 1/1/1 no ip address dhcp no shutdown ip address 100.67.166.32/24 management route 0.0.0.0/0 100.67.166.254 management route 0.0.0.0/0 100.67.166.254 7.2 Note: The configuration for the S3048-ON management switch is not shown. The configuration and deployment of the overall management network is not within the scope of this document. VLT configuration In this example, configure VLT between the two Dell EMC S5248F-ON switches. VLT synchronizes Layer 2 and ARP table information between the switches and enables a single port channel to be connected to the switch pair as if they are a single switch. 1. Set up VLT on S5248F-1 using the commands in the first column of Table 7 (recommended port values are shown). 2. Configure S5248F-2 using the commands in column 2 provided in Table 7. 17 Dell EMC Networking OS10 Enterprise Edition Deployment Guide with Cisco ACI

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34

17
Dell EMC Networking OS10 Enterprise Edition Deployment Guide with Cisco ACI
7
Configure S5248F-ON switches
The following section outlines the configuration commands that are issued to the Dell EMC Networking
S5248F-ON ToR switches.
7.1
OOB management configuration
The OOB port for the
Dell EMC Networking S5248F-ON
is
mgmt 1/1/1.
The following commands show
how to configure this OOB port when using OS10EE. The switches start at their factory default settings as
described in
Appendix A.1
.
Note:
The S5248F-ON CLI is accessible through the console port or by using SSH. The default username
and password are both
admin
.
OOB management configuration
S5248F-1
S5248F-2
configure terminal
hostname S5248F-1
interface mgmt 1/1/1
no ip address dhcp
no shutdown
ip address 100.67.166.33/24
management route 0.0.0.0/0
100.67.166.254
configure terminal
hostname S5248F-2
interface mgmt 1/1/1
no ip address dhcp
no shutdown
ip address 100.67.166.32/24
management route 0.0.0.0/0
100.67.166.254
Note:
The configuration for the S3048-ON management switch is not shown. The configuration and
deployment of the overall management network is not within the scope of this document.
7.2
VLT configuration
In this example, configure VLT between the two Dell EMC S5248F-ON switches. VLT synchronizes Layer 2
and ARP table information between the switches and enables a single port channel to be connected to the
switch pair as if they are a single switch.
1.
Set up VLT on S5248F-1 using the commands in the first column of Table 7 (recommended port
values are shown).
2.
Configure S5248F-2 using the commands in column 2 provided in Table 7.