Dell S5232F-ON EMC Networking OS10 Enterprise Edition Deployment Guide with Ci - Page 23

Verify configuration, 9.1 Validation using OS10EE CLI, 9.1.1 show vlt [domain-id] command

Page 23 highlights

9 Verify configuration This section covers methods to verify the Dell EMC ToR and ACI environment is configured properly. 9.1 Validation using OS10EE CLI The CLI commands that are shown in this section are available to help validate the configuration. The commands and output that are shown below are from an 5248F-ON switch. The CLI output from the second S5248F-ON, not shown, is similar. Note: The S5248F-ON CLI is accessible using SSH. The default username and password are both admin. 9.1.1 show vlt [domain-id] command The show vlt domain-id command validates the VLT configuration status. The role of one switch in the VLT pair is primary (not shown), and its peer switch is assigned the secondary role. The VLTi link Status and VLT Peer Status must both be up. S5248F-1# show vlt 127 Domain ID : 127 Unit ID : 1 Role : secondary Version : 2.0 Local System MAC address : 54:bf:64:be:f5:40 Role priority : 32768 VLT MAC address : 54:bf:64:ba:33:c0 IP address : fda5:74c8:b79e:1::1 Delay-Restore timer : 90 seconds Peer-Routing : Enabled Peer-Routing-Timeout timer : 0 seconds VLTi Link Status port-channel1000 : up VLT Peer Unit ID System MAC Address Status IP Address Version 2 54:bf:64:ba:33:c0 up fda5:74c8:b79e:1::2 2.0 23 Dell EMC Networking OS10 Enterprise Edition Deployment Guide with Cisco ACI

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34

23
Dell EMC Networking OS10 Enterprise Edition Deployment Guide with Cisco ACI
9
Verify configuration
This section covers methods to verify the Dell EMC ToR and ACI environment is configured properly.
9.1
Validation using OS10EE CLI
The CLI commands that are shown in this section are available to help validate the configuration. The
commands and output that are shown below are from an 5248F-ON switch. The CLI output from the second
S5248F-ON, not shown, is similar.
Note:
The S5248F-ON CLI is accessible using SSH. The default username and password are both
admin
.
9.1.1
show vlt [domain-id]
command
The
show vlt
domain-id
command validates the VLT configuration status. The role of one switch in the
VLT pair is primary (not shown), and its peer switch is assigned the secondary role. The VLTi link Status and
VLT Peer Status must both be up.
S5248F-1#
show vlt 127
Domain ID
: 127
Unit ID
: 1
Role
: secondary
Version
: 2.0
Local System MAC address
: 54:bf:64:be:f5:40
Role priority
: 32768
VLT MAC address
: 54:bf:64:ba:33:c0
IP address
: fda5:74c8:b79e:1::1
Delay-Restore timer
: 90 seconds
Peer-Routing
: Enabled
Peer-Routing-Timeout timer : 0 seconds
VLTi Link Status
port-channel1000
: up
VLT Peer Unit ID
System MAC Address
Status
IP Address
Version
--------------------------------------------------------------------------------
2
54:bf:64:ba:33:c0
up
fda5:74c8:b79e:1::2
2.0