Dell S5232F-ON EMC Networking OS10 Enterprise Edition Deployment Guide with Ci - Page 23
Verify configuration, 9.1 Validation using OS10EE CLI, 9.1.1 show vlt [domain-id] command
View all Dell S5232F-ON manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 23 highlights
9 Verify configuration This section covers methods to verify the Dell EMC ToR and ACI environment is configured properly. 9.1 Validation using OS10EE CLI The CLI commands that are shown in this section are available to help validate the configuration. The commands and output that are shown below are from an 5248F-ON switch. The CLI output from the second S5248F-ON, not shown, is similar. Note: The S5248F-ON CLI is accessible using SSH. The default username and password are both admin. 9.1.1 show vlt [domain-id] command The show vlt domain-id command validates the VLT configuration status. The role of one switch in the VLT pair is primary (not shown), and its peer switch is assigned the secondary role. The VLTi link Status and VLT Peer Status must both be up. S5248F-1# show vlt 127 Domain ID : 127 Unit ID : 1 Role : secondary Version : 2.0 Local System MAC address : 54:bf:64:be:f5:40 Role priority : 32768 VLT MAC address : 54:bf:64:ba:33:c0 IP address : fda5:74c8:b79e:1::1 Delay-Restore timer : 90 seconds Peer-Routing : Enabled Peer-Routing-Timeout timer : 0 seconds VLTi Link Status port-channel1000 : up VLT Peer Unit ID System MAC Address Status IP Address Version 2 54:bf:64:ba:33:c0 up fda5:74c8:b79e:1::2 2.0 23 Dell EMC Networking OS10 Enterprise Edition Deployment Guide with Cisco ACI