Dell XPS 400 9150 XPS 400/Dimension 9150 Service Manual - Page 23

Message, Possible Cause, Corrective Action

Page 23 highlights

Advanced Troubleshooting: Dell XPS 400 Service Manual 3-4-2 Screen retrace failure 3-4-3 Search for video ROM failure 4-2-1 No time tick 4-2-2 Shutdown failure 4-2-3 Gate A20 failure 4-2-4 Unexpected interrupt in protected mode 4-3-3 Timer-chip counter 2 failure 4-3-4 Time-of-day clock stopped 4-4-1 Serial or parallel port test failure 4-4-4 Cache test failure Message Possible Cause Corrective Action 8042 GateA20 error The keyboard controller failed its test. If you receive this message after you make changes in the system setup program, enter the system setup program and restore the original value(s). Address Line Short! An error in the address decoding circuitry in the memory has occurred. C: Drive Error C: Drive Failure The hard drive is not working or is not configured correctly. Reseat the memory modules. Ensure that the drive is installed correctly in the computer and defined correctly in the system setup program. Cache Memory Bad, Do Not Enable Cache The cache memory is not operating. See "Contacting Dell" in your Owner's Manual for instructions on obtaining technical assistance. CH-2 Timer Error An error is occurring on the timer on the system board. CMOS Battery State Low CMOS Checksum Failure CMOS System Options Not Set The system configuration information in the system setup program is incorrect or the battery charge may be low. See "Contacting Dell" in your Owner's Manual for instructions on obtaining technical assistance. Enter the system setup program, verify the system configuration, and then restart the computer. CMOS Display Type Mismatch CMOS Memory Size Mismatch CMOS Time and Date Not Set Diskette Boot Failure Drive A or B is present but has failed the BIOS POST. DMA Error Error in the DMA controller on DMA 1 Error the system board. Ensure that the drive is installed correctly in the computer and defined correctly in the system setup program. Check the interface cable at both ends. The keyboard or system board may need to be replaced. DMA 2 Error FDD Controller The BIOS cannot Ensure that the floppy drive or the hard drive is file:///T|/htdocs/systems/xps400/sm/adtshoot.htm[8/3/2012 3:11:19 PM]

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69

Advanced Troubleshooting: Dell XPS 400 Service Manual
file:///T|/htdocs/systems/xps400/sm/adtshoot.htm[8/3/2012 3:11:19 PM]
3-4-2
Screen retrace failure
3-4-3
Search for video ROM failure
4-2-1
No time tick
4-2-2
Shutdown failure
4-2-3
Gate A20 failure
4-2-4
Unexpected interrupt in protected mode
4-3-3
Timer-chip counter 2 failure
4-3-4
Time-of-day clock stopped
4-4-1
Serial or parallel port test failure
4-4-4
Cache test failure
Message
Possible Cause
Corrective Action
8042 Gate-
A20 error
The keyboard controller failed
its test.
If you receive this message after you make
changes in the system setup program,
enter
the system setup
program and restore the
original value(s).
Address Line
Short!
An error in the address
decoding circuitry in the
memory has occurred.
Reseat the
memory modules
.
C: Drive
Error
C: Drive
Failure
The hard drive is not working
or is not configured correctly.
Ensure that the drive is installed correctly in
the computer and defined correctly in the
system setup
program.
Cache
Memory Bad,
Do Not
Enable
Cache
The cache memory is not
operating.
See "Contacting Dell" in your
Owner's Manual
for instructions on obtaining technical
assistance.
CH-2 Timer
Error
An error is occurring on the
timer on the system board.
See "Contacting Dell" in your
Owner's Manual
for instructions on obtaining technical
assistance.
CMOS Battery
State Low
CMOS
Checksum
Failure
CMOS System
Options Not
Set
CMOS Display
Type
Mismatch
CMOS Memory
Size
Mismatch
CMOS Time
and Date Not
Set
The system configuration
information in the system
setup program is incorrect or
the battery charge may be
low.
Enter the system setup
program, verify the
system configuration, and then restart the
computer.
Diskette
Boot Failure
Drive A or B is present but
has failed the BIOS POST.
Ensure that the drive is installed correctly in
the computer and defined correctly in the
system setup
program. Check the interface
cable at both ends.
DMA Error
DMA 1 Error
DMA 2 Error
Error in the DMA controller on
the system board.
The keyboard or
system board
may need to be
replaced.
FDD
Controller
The BIOS cannot
Ensure that the floppy drive or the
hard drive
is