Epson U220B Technical Reference - Page 70

Selecting individual settings

Page 70 highlights

Selecting individual settings ❏ Basic serial interface setting To select transmission conditions, first choose "Serial interface settings"; then select "Data length, handshake, or parity." Press the FEED button the number of times required to select the desired "Serial interface settings" used for transmission conditions. Press FEED button 0 ~ 3 times: 4 times: 5 times: 6 times: 7 times: 8 times: 9 or more times: Setting selected No change 19200 bps 9600 bps 4800 bps 2400 bps 1200 bps No change bps: Indicates the number of transmitted bits per second (bps). ❏ Data length, handshake, or parity Press the FEED button the number of times required to select the desired "Data length, handshake, or parity" setting used for transmission conditions. Press FEED button 0 times: 1 time: 2 times: 3 times: 4 times: 5 times: 6 times: 7 times: 8 times: 9 times: 10 times: 11 times: 12 times: 13 or more times: Setting selected Data Length No change 8 bits 7 bits No change Handshake DTR/DSR control XON/XOFF control DTR/DSR control XON/XOFF control Parity No parity Even Odd No parity Even Odd No parity Even Odd No parity Even Odd 3-24 Setup Rev. D

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164

3-24
Setup
Rev. D
Selecting individual settings
Basic serial interface setting
To select transmission conditions, first choose “Serial interface settings”; then select “Data
length, handshake, or parity.”
Press the
FEED
button the number of times required to select the desired “Serial interface
settings” used for transmission conditions.
bps: Indicates the number of transmitted bits per second (bps).
Data length, handshake, or parity
Press the
FEED
button the number of times required to select the desired “Data length,
handshake, or parity” setting used for transmission conditions.
Press FEED button
Setting selected
0 ~ 3 times:
No change
4 times:
19200 bps
5 times:
9600 bps
6 times:
4800 bps
7 times:
2400 bps
8 times:
1200 bps
9 or more times:
No change
Press FEED button
Setting selected
Data Length
Handshake
Parity
0 times:
No change
1 time:
8 bits
DTR/DSR control
No parity
2 times:
Even
3 times:
Odd
4 times:
XON/XOFF control
No parity
5 times:
Even
6 times:
Odd
7 times:
7 bits
DTR/DSR control
No parity
8 times:
Even
9 times:
Odd
10 times:
XON/XOFF control
No parity
11 times:
Even
12 times:
Odd
13 or more times:
No change