Fluke 753 Fluke 750 Series User Manual - Page 113

Calibration Data, In Case of Difficulty, Service Center Calibration or Repair, User-Replaceable Parts

Page 113 highlights

Calibration Data The date of the last calibration and verification shows on the calibration sticker and on the calibration screen in Setup mode. The CAL. STATUS number on the sticker should always match the Calibration Status number in the calibration screen. Calibration of the Product is to be done by qualified personnel. See the 75X Series Calibration Manual available at the Fluke website. In Case of Difficulty Warning To avoid possible electric shock or personal injury, do not use the Product if it operates abnormally. Protection may be impaired. When in doubt, have the Product serviced. If the display is blank or unreadable, but the beeper works when the Product is turned on, make sure the brightness is correctly adjusted. To adjust the Intensity, see "Display Intensity". If the Product will not turn on, make sure the battery is not dead or disconnected from the battery charger. If the Product receives power, the power button should be lit. If the button is lit, but the Product does not power up, have the Product serviced. See "How to Contact Fluke". Documenting Process Calibrator User-Replaceable Parts Service Center Calibration or Repair Calibration, repairs, or servicing not included in this manual must be done only by qualified service personnel. If the Product fails, examine the battery pack first, and replace it if necessary. Make sure that you operate the Product in accordance with the instructions in this manual. If the Product is faulty, send a description of the failure with the Product. Pressure modules do not need to accompany the Product unless the module is faulty also. Be sure to pack the Product securely, using the original shipping container if it is available. See "How to Contact Fluke" and the Warranty Statement. User-Replaceable Parts Table 12 lists the Fluke part number of each userreplaceable part for the Product. See "Standard Equipment" and "Accessories" for model or part numbers of standard and optional equipment. 101

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128

Documenting Process Calibrator
User-Replaceable Parts
101
Calibration Data
The date of the last calibration and verification shows on
the calibration sticker and on the calibration screen in
Setup mode. The CAL. STATUS number on the sticker
should always match the Calibration Status number in the
calibration screen. Calibration of the Product is to be done
by qualified personnel. See the
75X Series Calibration
Manual
available at the Fluke website.
In Case of Difficulty

Warning
To avoid possible electric shock or personal
injury, do not use the Product if it operates
abnormally. Protection may be impaired.
When in doubt, have the Product serviced.
If the display is blank or unreadable, but the beeper works
when the Product is turned on, make sure the brightness
is correctly adjusted. To adjust the Intensity, see “Display
Intensity”.
If the Product will not turn on, make sure the battery is not
dead or disconnected from the battery charger. If the
Product receives power, the power button should be lit. If
the button is lit, but the Product does not power up, have
the Product serviced. See “How to Contact Fluke”.
Service Center Calibration or Repair
Calibration, repairs, or servicing not included in this
manual must be done only by qualified service personnel.
If the Product fails, examine the battery pack first, and
replace it if necessary.
Make sure that you operate the Product in accordance
with the instructions in this manual. If the Product is faulty,
send a description of the failure with the Product.
Pressure modules do not need to accompany the Product
unless the module is faulty also. Be sure to pack the
Product securely, using the original shipping container if it
is available. See “How to Contact Fluke” and the Warranty
Statement.
User-Replaceable Parts
Table 12 lists the Fluke part number of each user-
replaceable part for the Product. See “Standard
Equipment” and “Accessories” for model or part numbers
of standard and optional equipment.