Fluke 753 Fluke 750 Series User Manual - Page 20

Functions, Localized display 5 languages. See Display - calibration manual

Page 20 highlights

753/754 Users Manual Functions A summary of functions supplied by the Product is shown in Table 2. More features include: • Analog display for easy to read measurements when inputs are unstable. • Localized display (5 languages). See "Display Languages". • Thermocouple (TC) input/output jack and internal isothermal block with automatic reference-junction temperature compensation. Or manually record an external temperature reference. • Test results storage. • Data logging. Automatically log up to 8,000 data points. • A USB computer interface to upload or download tasks, lists, and results. • Automatic calibration procedures for transmitters and limit switches when you use split screen MEASURE/SOURCE mode. • Transmitter mode in which the Product can be configured to emulate the functions of a process instrument. • Calculator feature with square-root function, and accessible registers that contain measure and source values. • Damp feature (smoothes the last several readings), with display indicator of damped status. • Display of measurements in engineering units, percent of scale, square-law inputs, or custom units. • Min/Max feature captures and shows minimum and maximum measured levels. • Set source values to engineering units, percent of scale, square-law outputs, or custom units. • Manual and automatic stepping and an output ramp feature for testing limit switches. Trip detect is either a 1 V change or a continuity status change (Open or Short) from one ramp increment to the next. For performance testing and calibration instructions, download the 753/754 Calibration Manual from Fluke's website 8

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128

753/754
Users Manual
8
Functions
A summary of functions supplied by the Product is shown in
Table 2. More features include:
Analog display for easy to read measurements when
inputs are unstable.
Localized display (5 languages). See “Display
Languages”.
Thermocouple (TC) input/output jack and internal
isothermal block with automatic reference-junction
temperature compensation. Or manually record an
external temperature reference.
Test results storage.
Data logging. Automatically log up to 8,000 data points.
A USB computer interface to upload or download tasks,
lists, and results.
Automatic calibration procedures for transmitters and
limit switches when you use split screen
MEASURE/SOURCE mode.
Transmitter mode in which the Product can be
configured to emulate the functions of a process
instrument.
Calculator feature with square-root function, and
accessible registers that contain measure and source
values.
Damp feature (smoothes the last several readings),
with display indicator of damped status.
Display of measurements in engineering units, percent
of scale, square-law inputs, or custom units.
Min/Max feature captures and shows minimum and
maximum measured levels.
Set source values to engineering units, percent of
scale, square-law outputs, or custom units.
Manual and automatic stepping and an output ramp
feature for testing limit switches. Trip detect is either a 1
V change or a continuity status change (Open or Short)
from one ramp increment to the next.
For performance testing and calibration instructions,
download the
753/754 Calibration Manual
from Fluke’s
website