HP 1050c Service Manual - Page 125

Line Sensor

Page 125 highlights

NOTE Service Calibrations 2. Line Sensor The purpose of this Service Calibration is to calibrate the intensity of the line sensor in the Carriage PCA. An incorrect calibration can result in edge-detection failures during media loading and incorrect reading of prints that are used for alignment or calibration. Perform the Line Sensor Calibration whenever: n Edge detect procedure fails during media loading. n Carriage is disassembled or replaced. n Banding is detected in prints. n Misalignment between colors is detected. Perform the Line Sensor Calibration as follows: Make sure you load HP Coated media in to the Printer before performing this calibration. 1 In the Service Calibrations submenu, scroll to "2. Line Sensor cal" and press Enter. Service Calibrations 1. Accuracy cal... 2. Line sensor cal... 3. Service station... 4. Roller mark position... 5. Pen to Paper Spacing... Top Back ↑ Make Selection ↓ Enter Press Enter 2 The following message will appear asking you to confirm the operation. Select ACCEPT if you want to continue the Line Sensor Calibration, or select CANCEL if you want to cancel the it. Press Enter once the selection has been made. Line Sensor Calibration Accept Cancel Top Back ↑ Make Selection ↓ Enter Press Enter HP DesignJets 1050C and 1055CM Printers Service Manual 5-9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283
  • 284
  • 285
  • 286
  • 287
  • 288
  • 289
  • 290
  • 291
  • 292
  • 293
  • 294
  • 295
  • 296
  • 297
  • 298
  • 299
  • 300
  • 301
  • 302
  • 303
  • 304
  • 305
  • 306
  • 307
  • 308
  • 309
  • 310
  • 311
  • 312
  • 313
  • 314
  • 315
  • 316
  • 317
  • 318
  • 319
  • 320
  • 321
  • 322

Service Calibrations
5-9
HP DesignJets 1050C and 1055CM Printers Service Manual
2. Line Sensor
The purpose of this Service Calibration is to calibrate the intensity
of the line sensor in the Carriage PCA. An incorrect calibration can
result in edge-detection failures during media loading and incorrect
reading of prints that are used for alignment or calibration.
Perform the Line Sensor Calibration whenever:
Edge detect procedure fails during media loading.
Carriage is disassembled or replaced.
Banding is detected in prints.
Misalignment between colors is detected.
Perform the Line Sensor Calibration as follows:
NOTE
Make sure you load HP Coated media in to the Printer before
performing this calibration.
1
In the Service Calibrations submenu, scroll to "2. Line Sensor cal"
and press
Enter
.
2
The following message will appear asking you to confirm the operation.
Select
ACCEPT
if you want to continue the Line Sensor Calibration, or
select
CANCEL
if you want to cancel the it. Press
Enter
once the selection
has been made
.
Top
Enter
Back
Press Enter
Service Calibrations
3. Service station...
4. Roller mark position...
5. Pen to Paper Spacing...
1. Accuracy cal...
2. Line sensor cal...
Make Selection
Line Sensor Calibration
Cancel
Accept
Top
Enter
Back
Press Enter
Make Selection