HP 14.4kVA HP Monitored Power Distribution Unit User Guide - Page 91
HP Monitored PDU User's Guide, P-164000281-Rev 1
![]() |
View all HP 14.4kVA manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 91 highlights
Table 9. PDU CLI Objects (Continued) XML Object Name PDU.Gang[x].Pole[2].ReactivePower PDU.Gang[x].Pole[2].Statistic[4].Energy PDU.Gang[x].Pole[2].Voltage PDU.Gang[x].PowerFactor PDU.Gang[x].PresentStatus.OverCurrent PDU.Gang[x].PresentStatus.OverVoltage PDU.Gang[x].ReactivePower PDU.Gang[x].Statistic[3].Current PDU.Gang[x].Statistic[3].ModuleReset PDU.Gang[x].Statistic[3].Reset.Time PDU.Gang[x].Statistic[3].Time PDU.Gang[x].Statistic[4].Energy PDU.Gang[x].Statistic[4].ModuleReset PDU.Gang[x].Statistic[4].Reset.Energy PDU.Gang[x].Statistic[4].Reset.Time PDU.Gang[x].Type Serial Interface Operation Type HideMeasure HideMeasure HideMeasure Measure AlarmL1 AlarmL1 Measure Measure Command Measure Measure Measure Command Measure Measure Constant Description Unit Access Reactive Power provided by the pole. dVA RO R Energy counter since last reset. As it is reset to 0, the Wh RO related timestamp is updated with the current RTC value. Voltage Measured on the pole. cV RO Ratio of active power / apparent power provided by the breaker or outlet section. m% RO 0: No threshold triggered - RO 1: Warning low threshold triggered 2: Critical low threshold triggered 3: Warning high threshold triggered 4: Critical high threshold triggered 0: No threshold triggered - RO 1: Warning low threshold triggered 2: Critical low threshold triggered 3: Warning high threshold triggered 4: Critical high threshold triggered Reactive Power provided by the breaker/section. For a dVA RO double pole breaker, the reactive power for the two poles R is combined. Current peak consumption since last reset. mA RO As it is reset to 0, the related timestamp is updated with the current RTC value. When a value higher than the stored value is detected, the stored valued is overwritten. Command to Reset the stat. This command puts 0 in the - RW max and saves the current value of Timer. Timestamp saved when the stat reset is performed. s RO Timestamp saved at the moment where the current peak s RO consumption is reset. Energy counter since PDU startup. Wh RO For a double pole breaker, it is calculated as the accumulation of the two poles energy counter. Command to Reset the stat, This command does not put 0 - RW in the counter, but saves the current value of Energy timer into the data, Reset.Energy. Energy saved when the user resets the stat. Wh RO Timestamp saved when the user resets the stat. s RO Type of gang: - RO 1: Section of outlets (with 1 measurement) 2: Section of outlets (with 2 measurement, 1st method of wiring CT, current is max of 2 pole measures) 3: Section of outlets (with 2 measurement, 2nd method of wiring CT, current is sum of 2 HP Monitored PDU User's Guide P-164000281-Rev 1 85
![](/manual_guide/products/hewlettpackard-36kva-hp-monitored-power-distribution-unit-user-guide-9f24a2e/91.png)