HP 14.4kVA HP Monitored Power Distribution Unit User Guide - Page 92
PDU.Input[1].Phase[x].Current
![]() |
View all HP 14.4kVA manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 92 highlights
Serial Interface Operation Table 9. PDU CLI Objects (Continued) XML Object Name PDU.Gang[x].Voltage PDU.Input[1].ActivePower PDU.Input[1].ApparentPower PDU.Input[1].ChangedStatus.FrequencyOutOfRange PDU.Input[1].Frequency PDU.Input[1].Mode PDU.Input[1].Phase.Count PDU.Input[1].Phase[x].ActivePower PDU.Input[1].Phase[x].ApparentPower PDU.Input[1].Phase[x].ChangedStatus.OverCurrent PDU.Input[1].Phase[x].ChangedStatus.OverVoltage PDU.Input[1].Phase[x].Current PDU.Input[1].Phase[x].OverCurrent[1].Threshold PDU.Input[1].Phase[x].OverCurrent[3].Threshold PDU.Input[1].Phase[x].OverCurrent[4].Threshold PDU.Input[1].Phase[x].OverVoltage[1].Threshold PDU.Input[1].Phase[x].OverVoltage[2].Threshold PDU.Input[1].Phase[x].OverVoltage[3].Threshold PDU.Input[1].Phase[x].OverVoltage[4].Threshold PDU.Input[1].Phase[x].PeakFactor PDU.Input[1].Phase[x].PercentLoad PDU.Input[1].Phase[x].PhaseID PDU.Input[1].Phase[x].PowerFactor Type Measure Measure Measure Timestamp Measure Constant Constant Measure HideMeasure Timestamp Timestamp Measure Parameter Parameter Parameter Parameter Parameter Parameter Parameter Measure Measure Constant HideMeasure Description Unit Access Voltage Measured on the breaker/section. cV RO For a double pole breaker, it is the Li to Lj voltage. Active Power Measurement. dW RO It is the accumulation of 1 or 3 phase measures. Apparent Power Measurement. dVA RO It is the accumulation of 1 or 3 phase measures. s RO Frequency Measurement. dHz RO Wiring Mode - RO 0: Wye Measuring 1: Delta Measuring 2: Wye Current and Delta Measuring Number of phase managed by the Input module. - RO Active Power Measurement. dW RO Apparent Power Measurement. dVA RO Timestamp of last changing state of the alarm that has the s RO same name in the collection PresentStatus. Timestamp of last changing state of the alarm that has the s RO same name in the collection PresentStatus. Current Measurement. mA RO mA RW mA RW mA RW cV RW cV RW cV RW cV RW Crest factor of the current provided by the phase. m% RO Percent load consumed on the phase. It is the ratio: current % RO consumed / the nominal current of the PDU. Phase ID identifier depending of the wiring: - RO 1: Line 1 to Neutral 2: Line 2 to Neutral 3: Line 3 to Neutral 12: Line 1 to Line 2 23: Line 2 to Line 3 31: Line 3 to Line 1 Ratio of active power / apparent power provided by the phase. m% RO Value 0 to 100 for Cos PHI = 0.00 to 1.00 HP Monitored PDU User's Guide P-164000281-Rev 1 86
![](/manual_guide/products/hewlettpackard-36kva-hp-monitored-power-distribution-unit-user-guide-9f24a2e/92.png)