Page 105 highlights
Monitor Connector and Icon Pin Signal 1 Red Analog 2 Green Analog 3 Blue Analog 4 Not used 5 Ground 6 Ground 7 Ground 8 Ground DVI Connector Connector and Icon Pin Signal 1 T.M.D.S. Data2- 2 T.M.D.S. Data2+ 3 T.M.D.S. Data2/4 Shield 4 T.M.D.S. Data4- Pin Signal 9 +5V (fused) 10 Ground 11 Not used 12 DDC Serial Data 13 Horizontal Sync 14 Vertical Sync 15 DDC Serial Clock Pin Signal 13 T.M.D.S. Data3+ 14 +5V Power 15 Ground (for +5V) 16 Hot Pug Detect Monitor 95
![](/manual_guide/products/hewlettpackard-4000-maintenance-service-guide-hp-compaq-4000-pro-small-form-factor-business-pc-a540ffd/105.png)
Monitor
Connector and Icon
Pin
Signal
Pin
Signal
1
2
3
4
Red Analog
Green Analog
Blue Analog
Not used
9
10
11
12
+5V (fused)
Ground
Not used
DDC Serial Data
5
6
7
8
Ground
Ground
Ground
Ground
13
14
15
Horizontal Sync
Vertical Sync
DDC Serial Clock
DVI Connector
Connector and Icon
Pin
Signal
Pin
Signal
1
2
3
4
T.M.D.S. Data2–
T.M.D.S. Data2+
T.M.D.S. Data2/4 Shield
T.M.D.S. Data4–
13
14
15
16
T.M.D.S. Data3+
+5V Power
Ground (for +5V)
Hot Pug Detect