POST (Power On Self Test) Error Messages

Page 19 highlights

POST (Power On Self Test) Error Messages The Integrated Administrator (IA) has details containing new information it receives from the Blade Management Controller (BMC). You can use the IA syslog to determine when a fault occurred. Message 101-Option ROM Checksum Error 102/103-System Board error 162-System Options Not Set 163-Time & Date Not Set 164-Memory Size Error 201-Memory Error 301-Keyboard Error 303-Keyboard Controller Error 304-Keyboard or System Unit Error 1780-Disk 0 Failure 1792-No IDE fixed disk present Health LED Red Red Amber Amber Amber Red Amber Amber Amber Amber Corrective Action ● Clear CMOS. ● Flash ROM if necessary. ● Replace blade PC. ● Clear CMOS. ● Replace blade PC. ● Set time and date in Computer Setup. ● Replace RTC battery. ● Set time and date in Computer Setup. ● Replace RTC battery. ● Ensure DIMMs properly installed. ● Verify proper DIMM type. ● Remove and replace modules one at a time to isolate faulty module. ● Replace blade PC. ● Ensure DIMMs properly installed. ● Verify proper DIMM type. ● Remove and replace modules one at a time to isolate faulty module. ● Replace blade PC. ● Reconnect keyboard with blade PC turned off. ● Try different keyboard. ● Replace blade PC. ● Reconnect keyboard with blade PC turned off. ● Replace keyboard. ● Replace blade PC. ● Run Computer Setup DPS Self Test from Computer Setup. ● Replace hard drive. ● Check if hard drive is present. If so, run Computer Setup DPS Self Test from Computer Setup. ● Replace hard drive. POST (Power On Self Test) Error Messages 15

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23

POST (Power On Self Test) Error Messages
The Integrated Administrator (IA) has details containing new information it receives from the Blade
Management Controller (BMC). You can use the IA syslog to determine when a fault occurred.
Message
Health LED
Corrective Action
101-Option ROM Checksum Error
Red
Clear CMOS.
Flash ROM if necessary.
Replace blade PC.
102/103-System Board error
Red
Clear CMOS.
Replace blade PC.
162-System Options Not Set
Amber
Set time and date in Computer Setup.
Replace RTC battery.
163-Time & Date Not Set
Amber
Set time and date in Computer Setup.
Replace RTC battery.
164-Memory Size Error
Amber
Ensure DIMMs properly installed.
Verify proper DIMM type.
Remove and replace modules one at a time to isolate
faulty module.
Replace blade PC.
201-Memory Error
Red
Ensure DIMMs properly installed.
Verify proper DIMM type.
Remove and replace modules one at a time to isolate
faulty module.
Replace blade PC.
301-Keyboard Error
303-Keyboard Controller Error
Amber
Reconnect keyboard with blade PC turned off.
Try different keyboard.
Replace blade PC.
304-Keyboard or System Unit Error
Amber
Reconnect keyboard with blade PC turned off.
Replace keyboard.
Replace blade PC.
1780-Disk 0 Failure
Amber
Run Computer Setup DPS Self Test from Computer
Setup.
Replace hard drive.
1792-No IDE fixed disk present
Amber
Check if hard drive is present. If so, run Computer
Setup DPS Self Test from Computer Setup.
Replace hard drive.
POST (Power On Self Test) Error Messages
15