HP BladeSystem bc2800 Service Reference Guide: HP BladeSystem PC bc2000/bc2500 - Page 8

Removing a Blade PC, CAUTION

Page 8 highlights

Item 1 LED Unit Identification 2 Health 3 NIC A 4 NIC B 5 Drive activity 6 Power Status Off Blue Blue blinking Off Green Amber Red Red blinking Off Green Green blinking Off Green Green blinking Off Green blinking Off Amber Green Description Off Identification of blade PC Being remotely accessed Blade PC off Blade PC on and good health Blade PC degraded or power-up prohibited by the Integrated Administrator. Blade PC critical Blade PC critical No connection Linked to network Linked and activity on the network No connection Linked to network Linked and activity on the network No drive activity Drive activity No AC power to enclosure or blade PC Enclosure on and health good Blade PC power turned on 2. If the blade PC is active, notify the users and stop applications as necessary. 3. Shut down the operating system. This may shut off blade PC power. 4. If the blade PC still has power, power down the blade PC by either: ● Using the Integrated Administrator, or ● Pressing the power button (6) on the front of the blade PC. To perform an emergency shut down of the blade PC, press and hold the blade PC power button for four seconds. CAUTION: Performing an emergency shutdown on a blade PC may result in the loss of any unsaved data. Removing a Blade PC To remove a blade PC: 1. Power down the blade PC (Powering Down the BladeSystem PC on page 3). 2. Press the release latch (1). 4 Chapter 2 Removal and Replacement

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23

Item
LED
Status
Description
1
Unit Identification
Off
Blue
Blue blinking
Off
Identification of blade PC
Being remotely accessed
2
Health
Off
Green
Amber
Red
Red blinking
Blade PC off
Blade PC on and good health
Blade PC degraded or power-up prohibited by the
Integrated Administrator.
Blade PC critical
Blade PC critical
3
NIC A
Off
Green
Green blinking
No connection
Linked to network
Linked and activity on the network
4
NIC B
Off
Green
Green blinking
No connection
Linked to network
Linked and activity on the network
5
Drive activity
Off
Green blinking
No drive activity
Drive activity
6
Power
Off
Amber
Green
No AC power to enclosure or blade PC
Enclosure on and health good
Blade PC power turned on
2.
If the blade PC is active, notify the users and stop applications as necessary.
3.
Shut down the operating system. This may shut off blade PC power.
4.
If the blade PC still has power, power down the blade PC by either:
Using the Integrated Administrator, or
Pressing the power button
(6)
on the front of the blade PC.
To perform an emergency shut down of the blade PC, press and hold the blade PC power button for
four seconds.
CAUTION:
Performing an emergency shutdown on a blade PC may result in the loss of any unsaved
data.
Removing a Blade PC
To remove a blade PC:
1.
Power down the blade PC (
Powering Down the BladeSystem PC
on page
3
).
2.
Press the release latch
(1)
.
4
Chapter 2
Removal and Replacement