HP BladeSystem bc2800 Service Reference Guide: HP BladeSystem PC bc2000/bc2500 - Page 21

Disable Automated System Recovery in F10 Setup., POST under Recovery BIOS image

Page 21 highlights

6916-CPU Heatsink not properly attached Amber 6917-System was rebooted due to a potential lock up. Amber 6918-System Real Time Clock Oscillator not running within tolerance Amber 6919-Temperature and Power Monitoring Hardware failure 6920-Processor in Force-Throttle Mode Red Amber 6921-Blase System Management Controller firmware update failed. 6922-Blade temperature detected to be below 0 degrees Celsius 6923-CPU Temperature Monitoring Hardware failure 6924-Graphics Temperature Monitoring Hardware failure 6925-Blade/Enclosure Communication error Amber Amber Red Red Red 6927-Previous POST under Recovery BIOS Green 6928-POST under Recovery BIOS image Amber 6929-Blade performance is reduced due to Amber insufficient enclosure power and/or cooling NOTE: For bc2800 in a PC Blade Enclosure only ● Remove blade PC and check if heatsink is loose or not present. Tighten CPU heatsink screws to 8 inch-lbs of tension. ● Replace blade PC if message persists. ● Check event logs in operating system to ensure no software lockup. ● Disable Automated System Recovery in F10 Setup. ● Follow standard operating system debugging procedure. ● Reinstall system image. ● Replace CMOS battery. ● If the problem persists, replace blade PC. Replace blade PC. ● Ensure enclosure health LED is green and health status OK. If LED not green, troubleshoot enclosure. ● If enclosure health LED is green, check heatsink installation and operating ambient. Make sure every enclosure slot is filled with a blank or a blade PC. Reflash BMC firmware image. Check operating ambient. Operate the blade PC within environmental specifications. Replace blade PC. Replace blade PC. ● Swap blade PC to a different bay in enclosure and retest. ● Put blade PC into a different enclosure. If blade PC works in a different enclosure, troubleshoot original enclosure. ● Check for faulty Integrated Administrator module. ● Replace blade PC. Informational ● Reflash BIOS ● If message persists, replace blade PC. Remove the blade PC and insert it into a PC Blade Enclosure G2 or upgrade your enclosure with a PC Blade Enclosure G2 upgrade kit. POST (Power On Self Test) Error Messages 17

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23

6916-CPU Heatsink not properly attached
Amber
Remove blade PC and check if heatsink is loose or not
present. Tighten CPU heatsink screws to 8 inch-lbs of
tension.
Replace blade PC if message persists.
6917-System was rebooted due to a
potential lock up.
Amber
Check event logs in operating system to ensure no
software lockup.
Disable Automated System Recovery in F10 Setup.
Follow standard operating system debugging
procedure.
Reinstall system image.
6918-System Real Time Clock Oscillator
not running within tolerance
Amber
Replace CMOS battery.
If the problem persists, replace blade PC.
6919-Temperature and Power Monitoring
Hardware failure
Red
Replace blade PC.
6920-Processor in Force-Throttle Mode
Amber
Ensure enclosure health LED is green and health
status OK. If LED not green, troubleshoot enclosure.
If enclosure health LED is green, check heatsink
installation and operating ambient. Make sure every
enclosure slot is filled with a blank or a blade PC.
6921-Blase System Management
Controller firmware update failed.
Amber
Reflash BMC firmware image.
6922-Blade temperature detected to be
below 0 degrees Celsius
Amber
Check operating ambient. Operate the blade PC within
environmental specifications.
6923-CPU Temperature Monitoring
Hardware failure
Red
Replace blade PC.
6924-Graphics Temperature Monitoring
Hardware failure
Red
Replace blade PC.
6925-Blade/Enclosure Communication
error
Red
Swap blade PC to a different bay in enclosure and
retest.
Put blade PC into a different enclosure. If blade PC
works in a different enclosure, troubleshoot original
enclosure.
Check for faulty Integrated Administrator module.
Replace blade PC.
6927-Previous POST under Recovery BIOS
Green
Informational
6928-POST under Recovery BIOS image
Amber
Reflash BIOS
If message persists, replace blade PC.
6929-Blade performance is reduced due to
insufficient enclosure power and/or cooling
NOTE:
For bc2800 in a PC Blade
Enclosure only
Amber
Remove the blade PC and insert it into a PC Blade
Enclosure G2 or upgrade your enclosure with a PC Blade
Enclosure G2 upgrade kit.