Closed defect summary Solution IFLs are not being displayed for a backbone fabric. Fixed in DCFM 10.1.0 Symptom-IFLs are not being displayed in topology. For the link between a switch and a device, the nl selected connection properties section (in the connection properties table) is being removed. Symptom-User views the same port details in both columns of the selected connection properties section in the Connection Property table; moreover, most of the column in the section for the above scenario is always blank. Fixed in DCFM 10.1.0 Workaround-View the correct occupied port details connected to the switch using the switchshow CLI command. Active Zone Config tab shows inactive zones that were added to existing active config. Symptom-When the user adds inactive zones to active zone config, the Active Zone Config tab shows inactive zones immediately. Fixed in DCFM 10.1.0 Workaround-Closing and relaunching dialog displays proper information. Compare/Merge: adding/merging zone or zone config not moving zone/alias to RHS zone DB in some scenarios. Symptom-When user adds/merges zone or zone config from LHS zone DB to RHS zone DB, the alias and zone will not be moved to RHS view in some scenarios. Fixed in DCFM 10.1.0 Workaround-Manually add alias member to RHS side. Zoning dialog permitting creating zone and zone config with Default Zoning reserved names. Symptom-When the user enters Default Zoning reserved name for creating zoning element on the Zoning dialog, no warning message appears and the zoning element will be created successfully on Zoning dialog. Fixed in DCFM 10.1.0 Workaround-Rename the zone element with valid name and commit zone DB to destination. Added detached WWN-Name pairs and then nl performed discovery. The switch does not write name. Symptom-Switch and switch port Names configured before discovery will be overwritten with values discovered on the switch. Fixed in DCFM 10.1.0 Workaround-Discover switch and then assign Names to switches and switch ports. The switch values control the names in the application. Error messages enhancements. User with Read-Only Reports privilege can delete a report. Compare/Merge dialog is not showing progress bar/hourglass for any of the operation. Symptom-When the user performs an operation in the Compare/Merge dialog, the dialog does not display the progress bar or hourglass for any of the operation. Fixed in DCFM 10.1.0 Fixed in DCFM 10.1.0 Fixed in DCFM 10.1.0 Workaround- Wait still the changes are reflected in the Compare/Merge dialog. 12

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

Solution
Closed defect summary
Fixed in DCFM 10.1.0
IFLs are not being displayed for a backbone fabric.
Symptom—IFLs are not being displayed in topology.
Fixed in DCFM 10.1.0
Workaround—View the correct occupied port details
connected to the switch using the
switchshow
CLI
command.
For the link between a switch and a device, the
nl
selected connection properties section (in the connec-
tion properties table) is being removed.
Symptom—User views the same port details in both
columns of the selected connection properties section
in the Connection Property table; moreover, most of
the column in the section for the above scenario is
always blank.
Fixed in DCFM 10.1.0
Workaround—Closing and relaunching dialog
displays proper information.
Active Zone Config tab shows inactive zones that were
added to existing active config.
Symptom—When the user adds inactive zones to
active zone config, the Active Zone Config tab shows
inactive zones immediately.
Fixed in DCFM 10.1.0
Workaround—Manually add alias member to RHS
side.
Compare/Merge: adding/merging zone or zone
config not moving zone/alias to RHS zone DB in some
scenarios.
Symptom—When user adds/merges zone or zone
config from LHS zone DB to RHS zone DB, the alias
and zone will not be moved to RHS view in some
scenarios.
Fixed in DCFM 10.1.0
Workaround—Rename the zone element with valid
name and commit zone DB to destination.
Zoning dialog permitting creating zone and zone
config with Default Zoning reserved names.
Symptom—When the user enters Default Zoning
reserved name for creating zoning element on the
Zoning dialog, no warning message appears and the
zoning element will be created successfully on Zoning
dialog.
Fixed in DCFM 10.1.0
Workaround—Discover switch and then assign Names
to switches and switch ports. The switch values control
the names in the application.
Added detached WWN-Name pairs and then
nl
performed discovery. The switch does not write name.
Symptom—Switch and switch port Names configured
before discovery will be overwritten with values
discovered on the switch.
Fixed in DCFM 10.1.0
Error messages enhancements.
Fixed in DCFM 10.1.0
User with Read-Only Reports privilege can delete a
report.
Fixed in DCFM 10.1.0
Workaround— Wait still the changes are reflected in
the Compare/Merge dialog.
Compare/Merge dialog is not showing progress
bar/hourglass for any of the operation.
Symptom—When the user performs an operation in
the Compare/Merge dialog, the dialog does not
display the progress bar or hourglass for any of the
operation.