HP Brocade 8/12c HP StorageWorks B-series Data Center Fabric Manager Professio - Page 29

displays a warning message about the network, running on the same host, the Backup Option dialog

Page 29 highlights

Closed defect summary Solution No warning message is shown after clicking Next in the Copy Data and Settings screen of the DCFM Configuration wizard even if an unsupported or invalid directory is chosen as source for the migration. Symptom-No warning message is shown when the user clicks Next in the Copy Data and Settings screen of DCFM Configuration wizard. This occurs even if an unsupported or invalid directory is chosen as the source for the migration. Fixed in DCFM 10.1.0 Search feature in toolbar does not work for WWPN Fixed in DCFM 10.1.0 or WWNN. Information about Redirection zone needs to be provided in online help. Symptom-There is no reference to Redirection Zones in online help. Fixed in DCFM 10.1.0 Exceptions and Null error occur while refreshing data from server to client. Symptom-When refresh is selected, the following error is displayed: Could not contact DCFM server Null. Fixed in DCFM 10.1.0 Workaround-Restart client. Zoning dialog shows a message banner for switch level changes in a fabric scope. Symptom-A message banner appears in the Zoning dialog whenever FAS broadcast messages for the selected fabric scope. Fixed in DCFM 10.1.0 Backup Message should not be displayed when client and server are on the same host. Symptom-When both the client and server are running on the same host, the Backup Option dialog displays a warning message about the network location. Fixed in DCFM 10.1.0 Device ports zoned with domain, port config fails in Device connectivity zone diagnosis. Symptom-Diagnosis reports that device ports that are zoned are not. Fixed in DCFM 10.1.0 Zoning dialog: Reverse finding is failing in some scenarios when selected a zone member is part of a Chassis-based switch. Symptom-When a user invokes reverse finding after selecting a Domain or Port Index zone member from the Zones panel, the following message appears in the Zoning dialog: "no matches found." Fixed in DCFM 10.1.0 HP StorageWorks B-series Data Center Fabric Manager Professional 29

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

Solution
Closed defect summary
Fixed in DCFM 10.1.0
No warning message is shown after clicking Next in
the Copy Data and Settings screen of the DCFM
Configuration wizard even if an unsupported or invalid
directory is chosen as source for the migration.
Symptom—No warning message is shown when the
user clicks Next in the Copy Data and Settings screen
of DCFM Configuration wizard. This occurs even if
an unsupported or invalid directory is chosen as the
source for the migration.
Fixed in DCFM 10.1.0
Search feature in toolbar does not work for WWPN
or WWNN.
Fixed in DCFM 10.1.0
Information about Redirection zone needs to be
provided in online help.
Symptom—There is no reference to Redirection Zones
in online help.
Fixed in DCFM 10.1.0
Workaround—Restart client.
Exceptions and Null error occur while refreshing data
from server to client.
Symptom—When refresh is selected, the following
error is displayed:
Could not contact DCFM server Null.
Fixed in DCFM 10.1.0
Zoning dialog shows a message banner for switch
level changes in a fabric scope.
Symptom—A message banner appears in the Zoning
dialog whenever FAS broadcast messages for the
selected fabric scope.
Fixed in DCFM 10.1.0
Backup Message should not be displayed when client
and server are on the same host.
Symptom—When both the client and server are
running on the same host, the Backup Option dialog
displays a warning message about the network
location.
Fixed in DCFM 10.1.0
Device ports zoned with
domain
,
port
config fails
in Device connectivity zone diagnosis.
Symptom—Diagnosis reports that device ports that are
zoned are not.
Fixed in DCFM 10.1.0
Zoning dialog: Reverse finding is failing in some
scenarios when selected a zone member is part of a
Chassis-based switch.
Symptom—When a user invokes reverse finding after
selecting a Domain or Port Index zone member from
the Zones panel, the following message appears in
the Zoning dialog: “no matches found.”