HP Brocade 8/12c HP StorageWorks B-series Data Center Fabric Manager Professio - Page 34
Fixed in DCFM 10.1.4, Disable VF
![]() |
View all HP Brocade 8/12c manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 34 highlights
Closed defect summary Solution After the DCFM client accepted changes, the client was not updated and Fixed in DCFM 10.1.4 the discovery dialog was empty because the database connection was not closed. The CLI displays the NPIV device type for the attached node correctly as NPIV target, but the DCFM Product List displays the NPIV device type as NPIV initiator. The DCFM displays the encryption select target dialog host selection screen rather than select target dialog. Fixed in DCFM 10.1.4 DCFM displays the message Zone Member or Alias not found Fixed in DCFM 10.1.4 for a B-series slot/port member that exists as a domain and port member in the zone. The DCFM local client is slow and eventually hangs during discovery, preventing new clients from opening. A second local client nl displays the message contacting the server on login attempt and the remote client displays the message Server not available at port xxxxx. Fixed in DCFM 10.1.4 An ISL Offline event policy type action is not triggered when an ISL goes Fixed in DCFM 10.1.4 down. After an authentication failure, all switches in a fabric become unreachable and DCFM discovery does not recover. All switches have a blank or empty password field. Fixed in DCFM 10.1.4 nl Workaround prior to this upgrade: You could recover by entering the password in the discovery setup window for every switch in the nl affected fabric. After fabrics are discovered, ISLs disappear when a monitor or unmonitor Fixed in DCFM 10.1.4 operation is performed. After stopping services in the Server Management Console (SMC), the Fixed in DCFM 10.1.4 status bar does not indicate the same service status as the Services tab. ISL disappears in the Topology when the Seed Switch is changed from the switch running FOS 6.1 or earlier to a Non Default Logical Switch. Fixed in DCFM 10.1.4 On the HP StorageWorks 8/80 SAN Switch, four logical switches are allowed. If you have configured four logical switches, and you use the Logical Switches window to delete a switch and then create a new one, when you click OK to process the edits, the old logical switch is deleted, but the new one is not created. An error message appears, indicating that the maximum number of logical switches are present on the switch. Fixed in DCFM 10.1.4 Internal errors and slow response times occur on the host server during DCFM installation. Database timeouts are written to the log. Fixed in DCFM 10.1.4 Real-time performance graphs are not displayed for some end-to-end monitors and the following error message is written to the log Switch null in fabric has been removed from discovery. Real time performance data not available. Fixed in DCFM 10.1.4 Selecting Disable VF from the chassis group without discovering the default Fixed in DCFM 10.1.4 switch does not disable the VF; an error message appears. 34
![](/manual_guide/products/hewlettpackard-brocade-812c-hp-storageworks-bseries-data-center-fabric-manager-professional-101x-release-notes-56970804-2009-includes-101x-versions-7d9de41/34.png)