HP Brocade 8/12c HP StorageWorks B-series Data Center Fabric Manager Professio - Page 17
Workaround-Click Cancel before closing Options, LUNs in DCFM.
View all HP Brocade 8/12c manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 17 highlights
Closed defect summary Solution "No" and "Cancel" buttons have no functionality in confirmation message when moving across panels from IP Configuration after changing the Server IP. Symptom-Some changes are saved after clicking "No" or "Cancel" while moving to a new panel in the Options dialog from IP Configuration without saving changes. Fixed in DCFM 10.1.0 Workaround-Click Cancel before closing Options dialog. A full uninstall reports success after it fails when a DCFM is launched. Webtools remains active. Symptom-The install directory and subdirectories still exist after a full uninstall was reported as successful. Fixed in DCFM 10.1.0 Workaround-Make sure Webtools is closed before uninstall. To clean up, check if the install directory is removed. If it is not, then delete it. The user is not blocked from downloading the entire switch configuration (All) from one switch model to another for a particular scenario. Symptom-For a particular scenario, the error message indicating a mismatch of switch models is not shown after trying to replicate the entire switch configuration from one switch model to another. Because of this, the user is allowed to do configuration download on a switch using a switch configuration taken from a different switch model which is not recommended. Fixed in DCFM 10.1.0 Device Connectivity:Linux -3 of the results display nl "Index 0". Symptom-Three of the results displayed in the results dialog have "Index 0" displayed. The checks were for Device port check and Zone configuration. Fixed in DCFM 10.1.0 Tape Volume Label is not being displayed for tape LUNs in DCFM. Symptom-Tape Volume Label column does not display any data. Fixed in DCFM 10.1.0 DCFM causing many issues when a fabric is managed with a large zone DB. Symptom-When a user launches the Zoning dialog for a large zone DB (1MB), the dialog takes a long time and many zoning operations fail in the Zoning dialogue. Fixed in DCFM 10.1.0 Workaround-Manage large zone DB from fabric using CLI. Importing invalid zone DB xml file from Zoning dialog not showing validation error. Symptom-When a user imports an invalid xml file, no warning message appears from the Zoning dialog and nothing is imported to repository. Fixed in DCFM 10.1.0 Workaround-Verify and validate zone DB xml file manually before importing to offline repository. WebTools fails to launch for a switch running FOS V6.1.1. Symptom-Trying to launch WebTools page for a switch running FOS 6.1.1 may fail after a successful first launch. Fixed in DCFM 10.1.0 HP StorageWorks B-series Data Center Fabric Manager Professional 17