HP Brocade 8/12c HP StorageWorks B-series Data Center Fabric Manager Professio - Page 15
From Zone properties., tree also when an ISL is disabled.
View all HP Brocade 8/12c manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 15 highlights
Closed defect summary Solution Zoning Report not showing {D, P} alias members under Alias section. Symptom-When user generates report with {D,P} alias members, the report shows {D,P} section for each {D,P} alias member instead of members for each alias in the Alias section Fixed in DCFM 10.1.0 Zoning Report from Zoning dialog showing same zone members multiple times. Symptom-When user generates report from the Zone DB tab or Active Zone Config tab, the report shows the same zone member multiple times. Fixed in DCFM 10.1.0 In Zoning report, the Number of Members count is wrong when a zone contains different types of nl members including alias. Symptom-When user generates report, the Number of Members column shows wrong value when a zone contains aliases and other type members. Fixed in DCFM 10.1.0 Workaround-Get exact number of member count From Zone properties. Incorrect values are displayed for GbE port traffic in real time graph. Symptom-When traffic of about 139 MB/s is flowing through a GbE port, the throughput value displayed is around 18 MB/s which is much less. The same issue is noted for TX RX % Utilization also. Fixed in DCFM 10.1.0 The entire tunnel IDs that are free are not displayed in the tunnel ID drop-down in the configure tunnel step of FCIP config wizard. Symptom-Customer not able to see all the tunnel IDs that are free in the switch. Fixed in DCFM 10.1.0 The (-) symbol is not displayed on Fabric Node in product list if one of the ISLs between 2 switches is removed. Symptom-Indication should be displayed on product tree also when an ISL is disabled. Fixed in DCFM 10.1.0 DCFM does not update when Safe Zoning or Default Zoning is enabled/disabled using CLI, WT, or EFCM Basic. Symptom-DCFM, Zoning Policies dialog box, does not update when Safe Zoning or Default Zoning is enabled/disabled using CLI, WT, or EFCM Basic. Fixed in DCFM 10.1.0 Workaround-To obtain the right data, delete the fabric and perform rediscover. On creating a Port list/Node list View, visible attributes and order of columns in the product list are not set appropriately. Symptom-On creating Port list view or node list view, the order of columns in the product list is not changed as per requirement. Fixed in DCFM 10.1.0 Workaround-Manually change the order of the columns in the product list in the Port list view and Node list view. HP StorageWorks B-series Data Center Fabric Manager Professional 15